During the setup and installation phase, the applicable electro-technical regulations as well as the
directives regarding fire protection and the local construction police rules must be observed. The appliance
must be installed, operated and serviced properly according to this manual to warrant its flawless operation
and operational safety.
Attention! Possible material damages
If the Fresh & Smart is moved to a different location, the stops on the wheels must be released.
Also, all electrical couplings as well as possible mechanical attachments to surrounding furniture
must be detached. Always make sure that the connection cable is attached (e.g. using adhesive
tape) so that it cannot slip under the wheels.
4.1

Mechanical

Take the Fresh & Smart to the intended location. This location must be flat and clean.
Keep a minimum distance of 5 cm from flammable components, except the electrical supply line for the
Fresh & Smart.
When transporting the Fresh & Smart, do not travel over objects laying on the floor or protruding
from it; this can cause damage to the connection cable at the bottom of the appliance.
Also ensure that the suction module is "horizontal".
Use a level to ensure the balance.
In order to fix the appliance to the location, step on the wheel stops on the operator's side to lock them.
4.2

Electrical

Before starting the appliance up, check the mains supply and type of current. Especially check whether
these conform with the data on the type plate.
The directives DIN / VDE 0100 ff. and the technical connection conditions (TAB) of the public utility must
be adhered to.
The appliance is equipped with a connection cable with CEE plug to connect it to a facility receptacle.
Make sure that the 400 V / 32 A CEE receptacle on site is fused. Please note that the appliance could be
damaged if the neutral conductor is interrupted. The receptacle must be freely accessible in order to be
able to separate the appliance from the mains at any time. As an appliance with protection class 1, it must
always be connected to the protection conductor. The cable must be routed so that it cannot be crushed.
If in doubt, please consult an electrician.
If the connection cable of this appliance is damaged, it must be replaced by the manufacturer, his
customer service or an electrician to avoid hazards.
Equipotential connection for the additional local protection potential equalisation on site.
The symbol is located at the front and underneath the appliance bottom and shows the