Air Temp Sensor Short (Sa S); No Pod (No / Pod); Pumpjump Coil Short (Pj S); No Flow W/ Pump Jump(Lo F / Pod) - Heat Siphon Z Series Owner's Manual

Swimming pool heat pumps, 220volt -1 ph-60 hz only/220volt -1 ph-50 hz only/220volt -3 ph-50/60 hz/380/460 volt - 3 phase - 50/60 hz/440 volt - 3 phase - 60hz
Table of Contents

Advertisement

HEAT SIPHON

7.13 Air Temp Sensor Short (SA S)

WARNING CODE - See Air Temp Sensor Open Error above.

7.14 No POD (no / Pod)

SERVICE ERROR - No Pod Service Code means the Heat Siphon is looking for an external hardwired add
on Pod (See Accessories - J-POD, T-POD, S-POD) and it is shutting the Heat Siphon down because it has been
controlling a pump and no longer can detect or control the pump so to be on the safe side it shuts the heater and
POD terminals down and waits for user interaction.
• The error without a POD attached is rare but usually due to a power surge from storm, etc..
• This is easy to reset.
• Hold both Up and Down arrow keys at the same time
• As soon as they blink-hit the up or down key to scroll thru, Pool- Spa -Auto Pic
• Then you will see OFF. Stop at OFF and let the Heat Siphon shut OFF.
• Then Hit the up key 2 times to On.
• Heat Siphon will restart, go thru count down and NO POD error will be gone.
• The display will now go into its normal startup display and will show soft and software version
number then flow count down, then go into its time delay count before restarting

7.15 PumpJump Coil Short (PJ S)

ALERT CODE - The two wires going from the Player POD screw down terminals to a J-POD have a short circuit.
• You must have a J-POD for this Error to Occur.
• Check wiring and crimped wire connections for a short

7.16 No Flow w/ Pump Jump(Lo F / Pod)

ALERT CODE - Flow has NOT been detected with the J-POD, T-POD or S-POD connected while the Player is
sending the POD a 24 volt signal to turn the pool pump on
• Check connection on back of Player - wires should be connected to the "O" and "D" screw down
terminals.
• POD Toggle switch could be set to OFF which overrides Player signal keeping pump off

7.17 Flow w/ Pump Jump (FLO / Pod)

ALERT CODE - Flow has been detected with the J-POD, T-POD or S-POD connected while the Player is NOT
sending the POD a 24 volt signal to turn the pool pump on
• Check connection to Player - wires should be connected to the "O" and "D" screw down terminals
• POD Toggle switch could be set to ON which overrides Player signal and keeps pump on

7.18 Pod Coil Open (no / Pod)

ALERT CODE - An open circuit has been detected with a J-POD, T-POD or S-POD connected to the Player
• check connection on back of board
• wires should be connected to the "O" and "D" screw down ports.