Distance From The Spa; Pool Piping Required - Heat Siphon Z Series Owner's Manual

Swimming pool heat pumps, 220volt -1 ph-60 hz only/220volt -1 ph-50 hz only/220volt -3 ph-50/60 hz/380/460 volt - 3 phase - 50/60 hz/440 volt - 3 phase - 60hz
Table of Contents

Advertisement

HEAT SIPHON
longer the distance from the pool, the more heat loss from the piping. Since most of the time the piping is buried,
the heat loss is minimal for runs of up to 50 feet (50 feet to and from the pump = 100 feet total) unless the ground
is wet or the water table is high. A very rough estimate of heat loss per 100 feet of piping is 2500 BTU/Hr. for every
10°F difference in temperature between the pool water and the ground surrounding the pipe, which translates to
about a 3% to 5% increase in run time.

2.4 Distance from The Spa

CAUTION: Special consideration required using any heater with a spa or
hot tub. SEE APPENDIX D

2.5 Pool Piping Required.

IMPORTANT: Allow At Least 12 Inches Of Straight Pipe Between The
Heat Exchanger And Any Coupling Unions Or Elbows To Allow Backpanel
Removal For Servicing .
CAUTION: DO NOT USE ANY BYPASS PIPING. Heat Siphon® Requires
Full Flow From 25 T0 80 GPM. Installing A Bypass May Cause Short Cy-
cling Damage and Will Void Your Warranty.
The Dual-Fitting water ports allow you to glue either 1.5 inch or 2 inch (with a standard 2" PVC coupling)
schedule 40 PVC pipe directly into the heat exchanger. No metal heat sink piping is required. The following graphic
applies to all C & Z 200, 250,375 & 575 series heating only and cooling only models:
Heat Siphon's exclusive FULL FLOW Titanium heat exchanger has a minimal pressure drop and requires NO
SPECIAL PLUMBING arrangement. It should be considered as just another length of PVC pipe in your pool filtration
system.
Heat Siphon® Plumbing Installation
375HP / 575HP Models
in Basepan Hand Hole
Barb Fitting accepts
Plumb Schedule 40 PVC Pipe 1½" or 2" Diameter Directly into and out of Unit
FULL FLOW - NO BYPASS!!
For C & Z Series
200HP / 250HP,
Pipe Couplers
for Winterization
& Service Bypass
Condensate Drain
¾" Vinyl Tubing
Installer - 18
Installer Section
®
MINIMUM of 12" of Straight Pipe
between unit to couplers
for panel removal / service