Download Print this page

Memory Function; I Feel Function - Gree GWH18ND-K3NNA4A Service Manual

Hide thumbs Also See for GWH18ND-K3NNA4A:

Advertisement

There are 7 swing stat u s of horizontal louver: P osition s L, A, B, C and D, swing between L and D and stop at any position between L and
D (angle s between L and D are equiangular).
Upon turning off the unit, the horizontal louver will close at position 0 . Swing function is available only when swing function is set and
indoor fan is operating.
Note: If the position is set between L and B, A and C or B and D by remote controller, the horizontal louver will swing between L and D.
3.9 Display
3.9.1 Operation and Mode Icons
Upon energization, the unit will display all icons . Under standby state, running indicating mark is displayed in red. If the unit is started by
remote controller, running indicating mark gives off light ; meanwhile, the mark of current running mode will be displayed (mode LED:
co oling, heating and dry mode). If the light button is turned off, no mark will be displayed .
3.9.2 Display of Nixie Tube on Indoor Unit
When energized & started for the first time , the indoor unit defaults to display ing current set temperature (16 30 ). When set
temperature display is set by remote controller, it will display set temperature ; when room temperature display is set, it will display room
temperature. After that, when operat ing the remote controller for other settings, the temperature display method will keep original.
When operating the remote controller during room temperature display, the set temperature will be displayed for 5 seconds firstly and
then room temperature display returns.
"F1" will be displayed upon malfunction of room tempera ture sensor, "F2" upon malfunction of indoor unit tube temperature sensor and
"C5" upon malfunction of jumper cap.
For some models, if set temperature display is set by the remote controller, current set temperature will be displayed. After that, when
sw itch ing to room temperature display from set te mperature or outdoor temperature by the remote controller, room temperature will be
displayed for 5 seconds firstly and then set temperature display returns.
3.10 Locked protection to PG motor
I f the indoor f an motor keeps low rotation speed for a continuous period of time after startup , the unit will stop operation and display " H6 " .

3.11 Memory Function

Memor ized items: mode, up & down swing, light, set temperature and set fan speed.
When power is recovered after power failure , the unit will automatically start operation according to memor ized status . A fter power
recovery, t he unit without timer setting before power failure will operate according to the last setting ; t he unit with general timer setting
which has not been fulfilled before power failure will memorize the time r setting and re - calculate the time after.
4 Special Functions(Optional)
4.1 HEALTH Function
During operation of the indoor unit fan , press HEALTH button on the remote controller to start HEALTH function (If there is no t H EALTH
button on the remote controller, the unit defaults HEALTH function ON) .

4.2 I FEEL Function

When I FEEL command is received , the controller will operate according to the ambient temperature sent by the remote controller ( For
d efrosting and cold blow prevention , the unit operate s according to the ambient temperature sensed by the air conditioner). The remote
controller will regularly send ambient temperature data to the controller. When the data has not been received for a long time, the unit
will operate according to the temperature sensed by the air conditioner. If I FEEL function is not s el e c t ed , the ambient temperature will
be that sensed by the air conditioner . I FEEL function is not to be memorized .
0
O
L
A
B
C
D

Advertisement

loading