CLEANING INSTRUCTIONS - CBFX
Preventive Maintenance (cont.)
18 Install new auger seals on the front of
each drum.
19 Reinstall the augers. Rotate each
auger until it engages completely.
20 Lubricate the inner surface on each
bowl seal with food grade lubricant
(Curtis Part # WC-4916). Install a
bowl seal on the back of each bowl.
21 Set the mixing bowls back in place.
Make sure that the lip on the bottom
of each bowl rests inside the front
trim on the top of the chassis.
22 Replace the lids.
23 Remove and discard the existing tap
seals from the tap handle assemblies.
24 Install the new tap seals.
25 Lubricate the tap seal and the handle
mounting slots using food grade
lubricant.
26 Prepare the tap assembly for
attachment. Insert the top of the
spring into the hook on the bowl, as
shown. Insert the red rubber seal on
the back of the tap lever into the tap
hole on the bottom of the bowl. Line
up the middle pins on the tap lever
with the mounting slots.
27 Attach the tap handle assemblies.
Push in with your thumb on the center
of each tap lever handle until the
assembly pops into place.
CFBX, CLEANING INSTRUCTIONS
continued...
Auger
seal
Auger
18
19
21
22
Tap
seal
24
Put spring
into hook
Mount
Line up as
shown
Red seal
26
CI34
Bowl
seal
Old tap
seal
Bowl
DO NOT
push here
Push in
here
20
23
25
27