Reference: BIRT Unit, Swindon Please find enclosed the relevant Operation and Maintenance documentation for our works installed at the above. • Entrematic slider Manual If you require any further information please do not hesitate to contact me. Yours Faithfully, Hayley Stedmans...
Page 2
EntreMatic Sliding Door Operator EMSL User Manual AAE238...
Congratulations on your new automatic door! EntreMatic has developed automatic doors for more than 40 years. State-of-the-art technol- ogy and carefully tested materials and components provide you with a superior product. As with all other technical products, your automatic door requires periodic maintenance and service.
The EMSL is an automatic sliding door operator developed to make life easier for everyone who can benefit from automatic doors. The EMSL is designed to offer continuous use, a high degree of safety and maximum lifetime. The system is self-adjusting to the effects caused by normal variations in the weather conditions and to minor friction changes caused by e.g.
The closing starts when no “opening impulse” is received, the “hold open time” has ended and no “presence impulse” is activated. The EMSL user can select five different modes of operation if a programme selector is installed. See Programme selector functions on page 6.
Programme selectors The door functions are set with different key programme selectors. The key must always be removed on emergency escape doors after changing settings. Flush mounted Surface mounted PS-6 PSMB-5 PSMB-5 PS-5M PS-5M Programme selector functions “Off” This function is only used on emergency escape doors after it is certain that all people have left the building.
Technical data Mains power supply: 120 V AC -10% to 240 V AC +10%, 50/60 Hz, fuse 10 AT Power consumption: Max. 250 W Integrated safety To permit a safe passage between closing doors, the doors reverse immediately if an obstruc- tion is detected.
Page 9
Mechanical emergency unit (MEU) An elastic cord is used to open the door in the event of power failure. Until the power is restored, the door remains open. The operator will then resume the function set by the pro- gramme selector. The emergency unit is monitored by the operator control unit. A monitoring error means that the door opens and remains open until the error is cleared.
Fire doors Let the door close after an impulse ensuring nothing pre- vents the door from closing and locking (if regulations require it). = Contact your EntreMatic representative. For contact information, see last page. = Take appropriate measures. 1005274-EMEI-2.0 Issue 2009-06-17...
Page 11
≥ 25 CLEANING The best way to remove dust and dirt from the EMSL is to use water and a soft cloth or a sponge. A gentle detergent may be used. To maintain the quality of the enamel layer, the surfaces should be cleaned once/four months period.
Page 12
Activation by disabled people: Recommended, if applicable No entry, identifying one-way traffic: Mandatory in GB and US, if applica- Automatic door: Only mandatory in GB Keep clear: Only mandatory in GB = Contact your EntreMatic service representative. For contact information, see last page. 1005274-EMEI-2.0 Issue 2009-06-17...
Safety accessories Even though the EMSL is installed to comply with all applicable safety regulations, it is pos- sible to enhance safety/comfort with the following add-ons (please contact your local EntreMatic company for detailed description). – Combined motion and presence sensors –...
Page 14
selection, from a position where a test is not done to a position where the test is a demand. – Break-out unit PSB Enables the door/side screens to be broken outwards in case of emergency by applying a defined pressure (see page 7). –...
Prevent traffic using the door and allow it to do a complete opening and closing cycle with low speed. See “Programme selector functions” on page 6. PSMB-5 PS-6 See “Programme selector functions” on page 6. If the problem continues, please contact your EntreMatic representative. Issue 2009-06-17 1005274-EMEI-2.0...
Maintenance plan As mentioned earlier in this manual, service and adjustments performed by your EntreMatic- authorized representative will ensure safe and proper operation of your automatic door unit. The table below shows the recommended interval in revolutions, when to check or replace parts during preventive maintenance.
Need help?
Do you have a question about the EMSL and is the answer not in the manual?
Questions and answers