Package Contents
Choosing a Suitable
Site
S
WITCH
procedura di manutenzione, leggere le informazioni di sicurezza riportate
nell'Appendice A della presente guida per l'utente.
Switch unit
■
CD-ROM
■
Getting Started Guide (this guide)
■
Release Notes
■
Unit Information Labels
■
Warranty Information
■
Power Cord
■
2 x Mounting brackets
■
4 x Screws
■
4 x Rubber feet
■
The Switch is suited for use on a desktop, either free standing or
mounted in a standard 19-inch equipment rack. Alternatively, the Switch
can be mounted in a wiring closet or equipment room, as an aggregator
for other Hubs and Switches. A rack-mounting kit containing two
mounting brackets is supplied with the Switch.
CAUTION: Ensure that the ventilation holes are not obstructed.
When deciding where to position the Switch, ensure that:
Cabling is located away from:
■
sources of electrical noise such as radios, transmitters and
■
broadband amplifiers.
power lines and fluorescent lighting fixtures
■
The Switch is accessible and cables can be connected easily.
■
Water or moisture cannot enter the case of the Switch.
■
Air-flow is not restricted around the Switch or through the vents in the
■
side of the Switch. 3Com recommends that you provide a minimum of
25mm (1in.) clearance.
Air temperature around the Switch does not exceed 40
■
C (104
F).
°
°