1. DESCRIPTION.
The UMS-02 controller is a programmable time controller with universal application.
Its main purpose is to control external devices in the process of washing milk coolers and
milking devices, however it is also used, for example, in cleaning tanks for beer wort,
juice tanks, car washes, or juice production equipment.
The controller's casing in the UMS-02H version has an IP52 protection class and is
designed for built-in. Controller's electronics is able to work at temperature up to -10
The controller can work in an automatic cycle, according to one of four factory (default)
washing programs (with the possibility of their modification) or a program created by
the user. There is also the option of manually activating a vacuum pump or a stirrer.
2. TECHNICAL DATA.
casing dimensions
power supply
protection class:
- UMS-02
- UMS-02H
safety class
number of relay outputs
load capacity of the relay contacts
number of control inputs
type of display
number of available programs
number of factory (default) programs
maximum number of steps in each program
minimum duration of one step
maximum duration of one step
+48 537 872 522 (Sales Department)
+48 602 260 992 (Technical Department)
biuro@makot.pl
dt@makot.pl
123 x 68 x 85 mm
230 V AC 50 Hz
IP 20
IP 52
CE
6
10 A 250 V AC
2
(hydrostatic & external program start button)
LED
8
4
50
1 s.
99 min.
PPH MAKOT
ul. Przewóz 34/304
30-716 Kraków | Poland
www.makot.pl
(Sales Department)
(Technical Department)
O
C.
Page 1 of 13

Advertisement

loading
Need help?

Need help?

Do you have a question about the UMS-02 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MAKOT UMS-02

  • Page 1 (Technical Department) 1. DESCRIPTION. The UMS-02 controller is a programmable time controller with universal application. Its main purpose is to control external devices in the process of washing milk coolers and milking devices, however it is also used, for example, in cleaning tanks for beer wort, juice tanks, car washes, or juice production equipment.
  • Page 2 3. CONSTRUCTION. The UMS-02 controller is placed in a panel casing, intended for built-in, containing all control and executive elements: relays operation hydrostatic operation test mode signaling [6] program stop button [6] signaling [2] signaling [3] program start and pause button [5]...
  • Page 3 4. SCHEME OF CONNECTION OF THE CONTROLLER. Connecting the controller to the device that is to be controlled is illustrated by the following drawings: UMS-02 version UMS-02H version Page 3 of 13...
  • Page 4 ATTENTION 1. On the external start button and the hydrostatic input, the 230 V AC signal L should be given. 2. Relay no. 5 has normal open (NO) and normal closed (NC) inputs. 5. OPERATING THE CONTROLLER BY A DIRECT USER. The controller is characterized by the ease of use by a direct user.
  • Page 5 During the execution of the program, user can pause its execution at any time. This is done by re-pressing the start button (green) [5]. When the program is paused, all active relays are switched off. It is restarted by pressing the [5] button again. The program will be continued from the place where it was paused.
  • Page 6: Controller Functions

    6. CONTROLLER FUNCTIONS. The controller is equipped with a number of functions that, together with the possibility to create own program, allows the user to adapt the controller to the individual needs (see 7. PROGRAMMING and 9. SETTING TABLE). 1. Washing programs. The controller has 8 programs. Two programs for washing of milking devices and two programs for washing milk coolers are pre-programmed.
  • Page 7 switching in test mode to the next step during actual controller operation – this function is only available to the installer. 5. Function of returning to the factory (default) settings. If an error occurs while setting the controller operation, it is always possible to return to the factory settings. 6.
  • Page 8 ATTENTION Please do not provide access code to the direct users. The procedure for entering the access code, allowing entry into the settings and programming mode is shown below graphically: 7.1. Selection of the parameter to be edited. In the table of settings all available parameters (functions) are given along with their description and possible values to be set.
  • Page 9 7.2. Editing the program – parameter EdPr. The controller comes pre-equipped with 4 washing programs that can be freely edited, depending on needs. The remaining 4 places in the controller’s memory are intended for creating a program by the installer; they are empty (do not contain any steps). Each program can contain up to 50 steps (sequences), lasting from 1 second to 99 minutes.
  • Page 10 The test mode function is used for accelerated checking of the correct operation of the entire washing system, controlled by the UMS-02 controller. Working in the test mode consists in the possibility of manually going to the next steps of the program, without waiting for the end of the duration of a given step.
  • Page 11: Factory Programs

    ATTENTION After completing the testing, remember to return to the normal operating mode of the controller. During normal operation, the green diode A does not light up. 8. FACTORY PROGRAMS. The controller comes pre-equipped with 4 washing programs that can be freely edited, depending on needs.
  • Page 12 11:30 02:30 00:30 15:00 06:00 00:30 01:10:30 maximum total time PROGRAM NO. 3 no. of LED diode no. of relay comments no. of step step duration CW ZW PM PPR ZZ PMY 02:00 00:30 02:00 02:30 02:30 00:30 05:00 03:00 02:00 00:30 03:30...
  • Page 13 9. TABLE OF SETTINGS. DESCRIPTION OF THE FACTORY SYMBOL RANGE OF SETTINGS FUNCTION SETTING entry in settings U000 access code editing factory programs and 8 programs creating own programs – see – see editing the programs EdPr 7.2. Editing the program - 8.

This manual is also suitable for:

Ums-02h