Power Supply Unit Technical Specifications; Maintenance - FIAM. eTensil Use And Maintenance Manual

Electric screwdrivers with automatic shut off
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
pin-out Db 15 female

POWER SUPPLY UNIT TECHNICAL SPECIfICATIONS:

Specification
mains supply voltage
mains supply frequency
Rated power
operating temperature
power supply unit weight

MAINTENANCE

the tool signals when 1,000,000 cycles have been reached (the front light flashes in
rotation) and the need for an inspection which must be carried out by fiam technical
assistance.
if you do not wish to proceed with the inspection, the signal can be reset by following
the instructions given in the table on page 12, function no. 6.
if this option is taken, fiam declines all responsibility for subsequent damage or mal-
function.
for the system to work correctly we recommend the following rules be observed:
minimum pause between two successive tightening cycles = 3 times the tightening
time (e.g. 1 sec. tightening time, 3 secs. minimum pause between successive tight-
ening cycles).
Value
230 +/-10%
50-60
80
0-40
0,6
Unit
v a.c.
hz
W
°C
Kg
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents