Nivus NivuCompact Instruction Manual

Ultrasonic measurement device

Advertisement

Quick Links

Instruction Manual
NivuCompact
Ultrasonic Measurement Device NivuCompact
NIVUS GmbH
Im Taele 2
75031 Eppingen, Germany
Phone +49 72 62 - 91 91 - 0
Fax +49 72 62 / 91 91 - 999
E-Mail: info@nivus.com
Internet: www.nivus.com
NivuCompact - Rev. 05 as of 31.10.2012
Instruction Manual for
(Original Instruction Manual – German)
valid as of Software Revision No. 1.49
®
page 1

Advertisement

Table of Contents
loading

Summary of Contents for Nivus NivuCompact

  • Page 1 Software Revision No. 1.49 NIVUS GmbH Im Taele 2 75031 Eppingen, Germany Phone +49 72 62 - 91 91 - 0 Fax +49 72 62 / 91 91 - 999 E-Mail: info@nivus.com Internet: www.nivus.com NivuCompact - Rev. 05 as of 31.10.2012 page 1...
  • Page 2 ® Branch offices NIVUS AG NIVUS Sp. z o.o. Hauptstrasse 49 ul. Hutnicza 3 / B-18 8750 Glarus, Switzerland 81-212 Gdynia, Poland Phone: +41 (0)55 6452066 Phone: +48 (0) 58 7602015 Fax: +41 (0)55 6452014 Fax: +48 (0) 58 7602014 E-Mail: swiss@nivus.com...
  • Page 3 The use of general descriptive names, trade names, trademarks and the like in this handbook does not entitle the reader to assume they may be used freely by everyone. They are often protected registered trademarks even if not marked as such. NivuCompact - Rev. 05 as of 31.10.2012 page 3...
  • Page 4: Table Of Contents

    6.3.1 Maximum load for 2-wire and 3/4-wire operation ......18 6.3.2 2-wire connection ................19 6.3.3 3/4- wire connection ............... 19 6.3.4 Connection as Ex version .............. 20 6.3.5 Connecting options to NIVUS units ..........20 Overvoltage Protection ..............21 NivuCompact Installation ............... 22 6.5.1 General ..................22 6.5.2 Installation on open channels ............
  • Page 5 Trouble shooting ............... 38 Table of Resistiveness ............39 Maintenance and Cleaning ..........41 Emergency ................. 41 Dismantling/Disposal ............41 Table of Pictures ..............42 Index ................... 43 Declaration of Conformity ..........44 NivuCompact - Rev. 05 as of 31.10.2012 page 5...
  • Page 6: Ex-Approval

    ® Instruction Manual NivuCompact Ex-Approval The approval is only valid in connection with the respective indication on the transmitter nameplate. The complete EC-type examination certificate can be downloaded from http://www.nivus.com. page 6 NivuCompact – Rev. 05 as of 31.10.2012...
  • Page 7: Overview And Use In Accordance With The Requirements

    ® Instruction Manual NivuCompact Overview and use in accordance with the requirements Overview Display Keypad Terminal clamp housing Screw thread Fig. 2-1 Overview NivuCompact - Rev. 05 as of 31.10.2012 page 7...
  • Page 8: Use In Accordance With The Requirements

    Here the allowed maximum values, as specified in chapter 2.3 must be strictly kept. All cases which vary from these conditions and are not passed by NIVUS GmbH in writing are left at owner’s risk.
  • Page 9: Specifications

    Measurement range 0.2 m – 3 m 0.3 m – 6 m 0.3 m - 10 m Screw thread mounting 1.5“ BSP or NPT 1.5“ BSP or NPT 2“ BSP or NPT NivuCompact - Rev. 05 as of 31.10.2012 page 9...
  • Page 10: General Notes On Safety And Danger

    All operations, which go beyond steps to install, to connect or to program the device, must be carried out by NIVUS staff only due to reasons of safety and guarantee. 3.1.2 Special Danger Notes Please note that due to the operation in the waste water field transmitter, sensors and cables may be loaded with dangerous disease germs.
  • Page 11: Device Identification

    Sira 06ATEX2161X Electrostatic Hazard - clean only with a damp cloth Fig. 3-2 Nameplate of NivuCompact 3 i.s. with Ex approval This instruction manual is a part of the device and must be available for the user at any time.
  • Page 12: Turn-Off Procedure

    Before operating the device the user has to ensure, that the local regulations (e.g. for electric supply) on installation and initial start-up are taken into account, if this is both carried out by the user. page 12 NivuCompact – Rev. 05 as of 31.10.2012...
  • Page 13: Functional Principle

    Relays and mA output can be set to fall to defined conditions in case of errors (hold latest value, 3.5 mA or 22mA). If set to >volume measurement< the NivuCompact is capable of being used accordingly (Q/h using 16 break points). This mode will utilise the analog output as volume signal.
  • Page 14: Device Variations

    Please check your delivery according to the delivery note for completeness and intactness immediately after receipt. Any damage in transit must be instantly reported to the carrier. An immediate, written report must be sent to NIVUS GmbH Eppingen as well.
  • Page 15: Storing

    Transportation must be carried out in the original packaging. Return The NivuCompact must be returned at customer cost to NIVUS Eppingen in the original packaging. Otherwise the return cannot be accepted! NivuCompact - Rev.
  • Page 16: Installation

    500 kOhm min. is necessary. The section dimension of the power supply wires or the current loop wires shall meet the technical requirements of the NivuCompact. For information on device protection see chapter 2.3. Particularly regarding Ex protection measures it must be checked if the unit power supplies must be integrated into the facility’s emergency shutdown...
  • Page 17: Enclosure Dimensions

    ® Instruction Manual NivuCompact 6.2.2 Enclosure dimensions Fig. 6-1 NivuCompact 3 and 6 m Fig. 6-2 NivuCompact 10 m NivuCompact - Rev. 05 as of 31.10.2012 page 17...
  • Page 18: Transmitter Connection

    Transmitter Connection When opening the NivuCompact enclosure, please strictly avoid moisture (dew, drops etc.) or dirt to get into the NivuCompact electronics compartment. Water or dirt must not leak into the terminal housing. Please seal the clamp housing in a way that neither water nor dirt might leak in.
  • Page 19: 2-Wire Connection

    Terminal clamp 5: current loop output 4 - 20 mA (SOURCE Mode) Terminal clamp 6: +voltage output 0 to 5/10 V Terminal clamp 7: GND voltage output 0 to 5/10 V NivuCompact - Rev. 05 as of 31.10.2012 page 19...
  • Page 20: Connection As Ex Version

    +12 to 28 V DC current loop input Terminal clamp 2: current loop output (4-20 mA) Please observe the maximum permissible connected loads when connecting the NivuCompact i.s (Ex) (see chapter 2.3 Specifications). 6.3.5 Connecting options to NIVUS units Flow...
  • Page 21: Overvoltage Protection

    ® Instruction Manual NivuCompact Overvoltage Protection For effective protection of the NivuCompact it is necessary to protect power supply and mA outputs by using overvoltage protection devices. NIVUS recommends: DataPro 2x1-24V/24V TR for mA and voltage output of NivuCompact. Overvoltage protection is implemented by using leakage current of 20.000 A as well as automatic self-control using failsafe diodes.
  • Page 22: Nivucompact Installation

    NivuCompact Installation 6.5.1 General The NivuCompact echo sounder shall durably and reliably be installed in a way that the sensor face is adjusted in a right angle to the measurement medium. Fig. 6-11 Correct installation of the compact echo sounder Fig.
  • Page 23: Installation On Open Channels

    6.5.2 Installation on open channels If used in open channels please ensure to install the NivuCompact in the channel centre if possible and keep the distance to the measurement medium as short as possible (observe min. measurement range). If the measurement place...
  • Page 24: Installation On Containers, Silos And Tanks

    The compact echo sounder installation on containers, silos and tanks depends on the medium which is to be measured. The most important thing is to adjust the NivuCompact sensor face as perpendicular as possible (±2°) to the medium to be measured (see Fig. 6-11).
  • Page 25: Initial Start-Up

    NivuCompact Initial Start-up General Notes to the user Before you connect and operate the NivuCompact you should strictly follow the notes below! This instruction manual contains all necessary information to program and to operate the device. It is addressed to qualified technical personnel who have appropriate knowledge about measurement, automation and regulation technology.
  • Page 26: Operation Mode

    ® Instruction Manual NivuCompact Operation mode The NivuCompact has four different operation modes (select in P100): distance fill level empty space volume The operation mode defines the NivuCompact measurement mode. MODE 1 (distance) The distance measurement P100 = 1 measures the distance between measurement medium and sensor bottom edge and indicates the value on the display.
  • Page 27: Navigation Buttons

    Instruction Manual NivuCompact Navigation buttons There are 4 push buttons located on the top of the NivuCompact. They allow initial start-up as well as to set up/program the unit. Pressing enables to access individual “hotkey functions” as well. In the programming mode...
  • Page 28: Program Mode

    If your entry was successful the display will indicate >APP< for application. If however you input the wrong pass code the NivuCompact LC display will show “Fail” for 2 seconds and will revert back to operation mode.
  • Page 29: Analog Output Calibration

    Calibration of analog output (4-20 mA) as well as voltage output (0-10 V) has been carried out per default. If the current output value should be incorrect anyway, it may be adjusted anew using parameters P834 and P835 (only possible by using PC software). NivuCompact - Rev. 05 as of 31.10.2012 page 29...
  • Page 30: Calibration Ultrasonic Measurement

    Nitrate monoxide (10 °C) 1284 4213 Hydrogen STEAM (97 °C) Acetone Benzol Chloroform Ethyl alcohol Ethyl airwaves carbon tetrachloride 1099 Methanol 1621 Steam (134 °C) Fig. 8-3 Velocity of sound in gases (P860) page 30 NivuCompact – Rev. 05 as of 31.10.2012...
  • Page 31: Parameter List

    Hence the sensor is able to measure beyond its zero point without any loss of echo e.g.: P105 = 2 m ; P108 = 10% ; using far blanking = 2.20m total. NivuCompact - Rev. 05 as of 31.10.2012 page 31...
  • Page 32 Alarm is raised if the Failsafe Timer (P809) P223 Relay 2 “ON” Setpoint Level entry 0.00 P224 Relay 2 “OFF” Setpoint Level entry 0.00 page 32 NivuCompact – Rev. 05 as of 31.10.2012...
  • Page 33 P600 = 3 Rectangular Pyramid base P600 = 4 Cylindrical Parabola base P600 = 5 Cylindrical Half-sphere base P600 = 6 Cylindrical Flat sloped base P600 = 7 Rectangular Flat sloped base NivuCompact - Rev. 05 as of 31.10.2012 page 33...
  • Page 34 This parameter displays the actual maximum Max. Volume (Read Only) volume that has been calculated by the NivuCompact. P607 = P604 x P606 P610 -P641 0 – 9999 16 break points (adjustable only via PC) Linearisation page 34 NivuCompact – Rev. 05 as of 31.10.2012...
  • Page 35 Trim low mA value in case of error (can be set via PC only) 0 – 9999 Trim high mA value in case of error (can be set via PC only) NivuCompact - Rev. 05 as of 31.10.2012 page 35...
  • Page 36 Turn password request on or off Passcode 1 = ON P922 0000 – 9999 Change passcode, 1997 Passcode Attention: access to NivuCompact by using this password only! P926 Read Only Displays the current software revision P928 Read Only Displays the serial number of the unit...
  • Page 37 To exit the parameter setting mode press >ESC< several times until the display indicates „run“. Pressing the >ENTER<-key subsequently will take you to operation/measurement mode again. NivuCompact - Rev. 05 as of 31.10.2012 page 37...
  • Page 38: Troubleshooting

    Enter parameters in correct range of values Enter required parameter values before >Pd< on display Supply voltage too low Check power supply (Power down) Check connection wiring Remove communication cable page 38 NivuCompact – Rev. 05 as of 31.10.2012...
  • Page 39: Table Of Resistiveness

    Oils (unsaturated aliphatic alloys) acceptable Waxes (heavy oil) acceptable Petrol / gasoline acceptable Coolant solution (Glycol) acceptable Break fluid (heavy alcohols) acceptable Cleaning agent acceptable Water, hot (> 80°C) not recommended NivuCompact - Rev. 05 as of 31.10.2012 page 39...
  • Page 40 Sharp mineral acids acceptable weak organic acids acceptable Sharp organic acids acceptable oxygenate acids conditionally resistant weak leaches acceptable Sharp lye not recommended Trichloroethylene acceptable Perchlorethylene acceptable Acetone not recommended Alcohols acceptable page 40 NivuCompact – Rev. 05 as of 31.10.2012...
  • Page 41: Maintenance And Cleaning

    The device Type NivuCompact is designed to be virtually maintenance-free and free of material wear. If required clean the transmitter enclosure if with a dry, lint-free cloth. For heavy pollution NIVUS recommends the use of surface-active agents.
  • Page 42: Table Of Pictures

    Overview ............................7 Fig. 3-1 Nameplate of NivuCompact 3 without Ex approval ..............11 Fig. 3-2 Nameplate of NivuCompact 3 i.s. with Ex approval ..............11 Fig. 4-1 Type keys for NivuCompact ......................14 Fig. 6-1 NivuCompact 3 and 6 m ......................17 Fig.
  • Page 43: Index

    Use in accordance with the requirements ..8 Maintenance ..........41 Maximum volume ........34 Vessel Shape ..........33 Volume Menu ..........33 Names ............3 Navigation buttons ........27 Notes ............10 Warnings ............10 NivuCompact - Rev. 05 as of 31.10.2012 page 43...
  • Page 44: Declaration Of Conformity

    E-Mail: info@nivus.com Internet: www.nivus.de Für das folgend bezeichnete Erzeugnis: For the following product: Le produit désigné ci-dessous: Bezeichnung: Kompactecholot NivuCompact 3, 6, 10 Description: Compact echo sounder Désignation: Capteur compact á traitement d´nécho NMC0P03…/…06…/…10… Typ / Type: erklären wir in alleiniger Verantwortung, dass die auf dem Unionsmarkt ab dem Zeitpunkt der Unterzeichnung bereitgestellten Geräte die folgenden einschlägigen Harmonisierungsvorschriften der Union erfüllen:...
  • Page 45 E-Mail: info@nivus.com Internet: www.nivus.de Für das folgend bezeichnete Erzeugnis: For the following product: Le produit désigné ci-dessous: “Ex“ Kompaktecholot NivuCompact 3 i.s., 6i.s., 10 i.s. Bezeichnung: “Ex” Compact echo sounder Description: “Ex”Capteur compact á traitement d ´écho Désignation: Typ / Type: NMC0P03xE / NMC0P06xE 7 NMC0P10xE erklären wir in alleiniger Verantwortung, dass die auf dem Unionsmarkt ab dem Zeitpunkt der Unterzeichnung...

Table of Contents