1. Standard setting at the gas combination valve
Make the standard settings at the gas
NB
combination valve in accordance with the
table. Otherwise there is a risk of damage to
the appliance.
Carefully turn the screw fully home and then undo as
follows:
Standard setting for different gas types: Turn anti-
clockwise.
Gas type
G20
G31
2. Replacing the gas combination valve and the gas
restrictor
a) Undo the electrical connections at the gas combination
valve (GCV) (3 screws).
b) Undo the mixer with its mounting plate and inlet pipe
from the fan (3 screws).
3062883_0910
Conversion to G31
Zero point
1 ¾ turns
1 ¾ turns
Fig.: Gas combination valve.
Fig.: Gas combination valve.
Zero point
screw, Tx40
Torx (under
the cover)
3 screws
3 screws