Hide thumbs Also See for MagCore HF48:

Advertisement

Quick Links

Operation Manual
CONTENTS
━ Operation Parameters . . . . . . . . . . . . . . . . . . . 2
━ Operation Environment . . . . . . . . . . . . . . . . . . 2
━ Applications . . . . . . . . . . . . . . . . . . . . . . . . . . 2
━ Before Installation . . . . . . . . . . . . . . . . . . . . . . 5
━ Install MagCore . . . . . . . . . . . . . . . . . . . . . . . 6
━ Install Tip and Sample Tube . . . . . . . . . . . . . . . . 7
━ Install Elution Tube . . . . . . . . . . . . . . . . . . . . . . 7
━ Install Cartridge . . . . . . . . . . . . . . . . . . . . . . . . 7
━ Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . 8
━ Panel Functional Area . . . . . . . . . . . . . . . . . . . . 8
━ Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
━ Save Programs . . . . . . . . . . . . . . . . . . . . . . . .12
━ Delete Programs . . . . . . . . . . . . . . . . . . . . . . .12
Update Program Files . . . . . . . . . . . . . . . . . . . . .13
━ Replace O-Rings . . . . . . . . . . . . . . . . . . . . . . .14
━ Clean Piercing Needles . . . . . . . . . . . . . . . . . . .14
━ Piston Test . . . . . . . . . . . . . . . . . . . . . . . . . . .15
━ Rejection Tip . . . . . . . . . . . . . . . . . . . . . . . . .16
━ Heater Test . . . . . . . . . . . . . . . . . . . . . . . . . .16
━ UV Sterilization . . . . . . . . . . . . . . . . . . . . . . . .17
━ Replace UV Lamp . . . . . . . . . . . . . . . . . . . . . .17
━ Moving Test . . . . . . . . . . . . . . . . . . . . . . . . . .18
━ DC Motor Operate . . . . . . . . . . . . . . . . . . . . .18
Ver. 2017-3
www.rbcbioscience.com
1
━ System Timing Setting . . . . . . . . . . . . . . . . . . . . .19
2
━ Export Error Record File . . . . . . . . . . . . . . . . . . . . .20
3
━ Replace Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .21
4
━ Barcode Scan . . . . . . . . . . . . . . . . . . . . . . . . . . .21
5
8
9
11
13
19
20
21
22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MagCore HF48 and is the answer not in the manual?

Questions and answers

Summary of Contents for RBC Bioscience MagCore HF48

  • Page 1: Table Of Contents

    Operation Manual CONTENTS Safety Precautions ━ System Timing Setting . . . . . . . . . . . . . . . . . . . . .19 Setup Specification System Information...
  • Page 2: Safety Precautions

    Safety Precautions Before use These WARNINGS and CAUTIONS are intended to protect you and other persons from injuries and damages To ensure safe operation, please follow them carefully SAFETY INSTRUCTIONS CAUTIONS 1. Read Instructions – All the safety and operating instructions should be read before the product is operated.
  • Page 3: Specification

    MagCore® HF48 Specification Model HF48 / MCA4801 (under development) Processing Capacity Max 48 samples per batch System Feature 1 Special Cartridge rack, T-Rack, Tube Rack design for easy installation 2 Auto-cartridges locking Power Supply Voltage: AC 200V ~ 220V; Frequency: 50/60Hz; Dimension W1000 x D800 x H1600 (mm) W39 37 X D31 49X H62 99(inches)
  • Page 4: Attachments

    Cartridge Carrier B X 1 / Cartridge Carrier A X 1 Tip Carrier B X 1 / Tip Carrier A X 1 Elution Carrier X 1 Power Cord X 1 Lubricant X 1 O-Ring X 24 MagCore HF48 Totle Weight 250kg / 551 25Lb www.rbcbioscience.com...
  • Page 5: System Overview

    MagCore® HF48 System Overview Status Indicator Viewing Window Touch Screen Door of Viewing Window Feeding Door Top Cover of Part Chamber Cooling Fans Power Switch and Plug Power Switch (red) Light Switch (green) Part Chamber Maintenance Cover Piston Assembly Operating Area B Storage Cabinet and Electrical Box Operating Area A Elution Area...
  • Page 6: Installation

    Installation ━ Before Installation Please find out a flat position close to outlet and keep sufficient space for system installation and ventilation before installation. System Depth 800 mm System Height 1600 mm Distance from Wall (left/right) Distance from Wall (back) 200 mm System Width 400 mm...
  • Page 7: Install Magcore

    MagCore® HF48 ━ Install MagCore Please refer to the position reference shown on page 5, locate the system in an appropriate place, put down the four fixed stands for fine-tuning according to the ground level, and tighten fixed screws Next Step Shear the belts on Racks Next Step Rotate and pull out the fixed bolts on both sides of the top cover of...
  • Page 8: Install Tip And Sample Tube

    ━ Install Tip and Sample Tube ━ Install Cartridge Insert Cartridge into Cartridge Rack, and then place Cartridge Rack in Cartridge Carrier After that, place the entire set of Cartridge Insert Tip and Sample Tube into the slots of Tip Carrier After that, Carrier in the slots of A area and B area according to marks, place the entire set of Tip Carrier in the slots of A area and B area respectively...
  • Page 9: Touch Panel And User Interface

    MagCore® HF48 Touch Panel and User Interface MagCore® HF48 provides 8 9-inch full-color touch screen and easily understood user operation interface The operator may see the current execution status and end time of the system by only watching the screen ━...
  • Page 10: Emergency Stop And Warning

    Emergency Stop and Warning Please read this safety information such that the system can be immediately stopped when emergency occurs. Method 1 Method 2 Removal Processing Processing Warning? Heater B 68°C / 154.4 °F | Heater A 68°C / 154.4 °F Heater B 68°C / 154.4 °F | Heater A 68°C / 154.4 °F Heating Program Stopped.
  • Page 11: Start

    MagCore® HF48 ━ Start Start 48 Test 24 Test Start Cartridge Code Stop 105 Plasma DNA Extraction Kit (1.2 ml) Dnase Treatmen Sample Volume Save 200 µl Start Elution Buffer Elution Volume Load Program 150 µl Back Press START to Proceed When you finish input and press Start key, the system will show a confirmation window, on which there are the parameters you Load program...
  • Page 12: Load Program

    Load Program You may memorize your commonly used programs in the system by self- defined names to simplify the convenience of system operation Load program Please select one of your programs Stored Programs Load program Maintenance Stored Program 1 Stored Program 5 Start Stored Program 2 Stored Program 6...
  • Page 13: Save Programs

    MagCore® HF48 ━ Save Programs ━ Delete Programs You may memorize your 8 most commonly used programs in You may delete your commonly used parameters from memory memory and create names for you to remember easily Start Start 24 Test 48 Test Start 24 Test...
  • Page 14: Update Program Files

    Easy Maintenance Easy Maintenance is for user’s maintenance items, including systems such as sterilization, cleaning, easy test and error message report. User has to arrange maintenance items regularly to make sure that the system is in good status Maintenance UV Sterilization UV Sterilization Maintenance Piston Test...
  • Page 15: Replace O-Rings

    MagCore® HF48 ━ Replace O-Rings ━ Clean Piercing Needles O-Ring & Piercing Needles O-Ring & Piercing Needles Replace O-Rings Clean Piercing Needles Replace O-Rings Clean Piercing Needles Start Start Stop Stop Select item and Press Start to run Back Select item and Press Start to run Back Select Replace O-Rings item and press START key to start Select Clear Piercing Needles, and press START to start...
  • Page 16: Piston Test

    ━ Piston Test Maintenance O-Ring & Piercing Needles Piston Test Step 2 Replace O-Rings Clean Piercing Needles UV Sterilization Moving Test Start Tip will absorb water from Sample Tube, please check the liquid level of each columns are at same horizontal. Stop Piston Test Heater Test...
  • Page 17: Rejection Tip

    MagCore® HF48 ━ Rejection Tip ━ Heater Test This function is mainly for the system to perform rejection after heat block well 1 emergency stop or operation interrupt due to outage etc. Maintenance UV Sterilization Moving Test Piston Test Heater Test O-Ring &...
  • Page 18: Uv Sterilization

    ━ Replace UV Lamp ━ UV Sterilization Maintenance UV Sterilization Moving Test Piston Test Heater Test O-Ring & Piercing Needles Rejection Tip Update Program Files DC Motor Operate Please select Item Back Select UV Sterilization in Maintenance menu. Next Step UV Sterilization Open the top cover of the part chamber 30min...
  • Page 19: Moving Test

    MagCore® HF48 ━ Moving Test ━ DC Motor Operate Maintenance Maintenance UV Sterilization Moving Test UV Sterilization Moving Test Piston Test Heater Test Piston Test Heater Test O-Ring & Piercing Needles Rejection Tip O-Ring & Piercing Needles Rejection Tip Update Program Files Update Program Files DC Motor Operate DC Motor Operate...
  • Page 20: System Timing Setting

    Setup You may set timing here Setup ━ System Timing Setting Select the items you want to change 2012 Load program Maintenance Start Backspace Setup Status 2012.06.07 Enter 12:12:12 Next Step Cancel Press Enter to send 12 or 24 hour form may be set Year Setting Enter setting value and press Enter to confirm Time Setting...
  • Page 21: System Information

    MagCore® HF48 System Information The system information records UI version, PLC version, system serial number, UV lamp operating time and reset and machine error list and output Status ━ Export Error Record File You may export error messages the system ever occurred from the touch panel to provide for engineers to determine the error or failure message generated by the system Status...
  • Page 22: Others

    Others ━ Replace Fuses ━ Barcode Scan 250V 5A You can use the barcode scanner to input your sample’s code into the test report Barcode Scan Start 48 Test 24 Test Start Cartridge Code Stop Dnase Treatmen Sample Volume Save Elution Buffer Elution Volume Load...
  • Page 23: Troubleshoots

    Troubleshoots Trouble Possible Causes Recommendations Liquid dropped on tube cartridge Suction leakage, due to damage or wear of Recommendations holder or T-holder O-Ring of piston Please refer to system test and check liquid levels of each column are at the same horizontal. Wrong liquid quantity moved 1 Suction head might be bent 1 Check suction head...
  • Page 24 TEL : +886-2-8912-1200 FAX : +886-2-8912-1300 3F., No.132, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 23145, TAIWAN http://www.rbcbioscience.com...

Table of Contents