Impulse System Mpt 700 - Honeywell Krom Schroder PFU 780 Technical Information

Burner control unit
Table of Contents

Advertisement

Accessories
MPT 700
L1
30z
F1
30b
30d
28z
N
28b
28d
32z
PE
32b
32d
20z
1
mA
GND
20b
2
20d
mA
18z
0 – 100%
18b
GND
18d
100% – 0
E1
14z
12–24 V
E2
14d
E3
16z
14b
0 V
16b
PFU 780 · Edition 02.12l
2b
12–24 V
4b
10b
0 V
12b
2z
A1
8888
2d
A2
4z
A3
88
4d
A4
6z
A5
6d
A6
8z
A7
8d
A8
/
10z
1
/
10d
2
12z
µC
6b
COM
8b

8 .11 Impulse system MPT 700

With 11 outputs for activation of burner control units
PFU 780. The furnace atmosphere is circulated thanks
to intermittent operation, and thereby constant tem-
perature distribution and shorter heating-up periods for
all gas-fired heat treatment furnaces are ensured.
Mains voltage: 95–240 V AC, ± 10%, 50/60 Hz.
Power consumption: 10 VA.
Additional auxiliary voltage:
12–24 V DC, ± 10%, max. 1.1 A.
Controller inputs: 2 x 0(4)–20 mA with common earth,
floating, load impedance approx. 225 Ω.
Three-point step input: floating, 12–24 V DC, load im-
pedance approx. 2.7 kΩ.
Digital inputs E1–E3: with common earth, floating,
12–24 V DC, load impedance approx. 2.7 kΩ.
Order No. 84395050
Further information can be found in brochure MPT.
61