9 Troubleshooting

9.1 Fault display(12-18Kbtu/h)

Display Definition of fault or protection
P3
Primary/secondary overcurrent protection
P4
Exhaust overheating protection
P5
Condenser high temperature protection
P6
Module protection
P9
Outdoor DC fan motor fault
H0
Communication fault between main board and drive
board
Current problem and can't recover
F3
F4
Ambient temperature sensor fault
F6
Condenser temperature sensor fault
F9
Outdoor unit fan motor problem

9.2 Fault display(24-60Kbtu/h)

Display Definition of fault or protection
E1
Three-phrase power phase sequence fault
E2
Communication fault between the outdoor unit and
the mast
E4
Temperature sensor fault
214
Remark
3 time of P4 protection appears within 100
minutes and then H6 occurs
3 times of P6 protection appears within 30
minutes and then H4 occurs
Display H9 after 2 times of P9 protection within 10
10 minutes
3 times p3 in 60 minutes
Remark
Communication is interrupted for more than 2
minutes , 20 minutes after the initial power-on or
within 20 minutes