Cancel Ignition Control

i)
Take out connection to the Ignition pin.
ii)
Press and hold button for around 15 seconds until the 3 LED battery type flash at the same time.
iii)
Release button and charger is changed to Input Voltage Control.
Input Voltage Control Mode
This mode requires increased voltage (>13.4V) of the starter battery which is only possible with short thick
cable connection and a non-intelligent alternator with sufficiently high and stable charging voltage. This
Control Mode is not suitable for modern cars due to wide voltage range such as Euro 5/6.
Cancel the Ignition Control first in order to get into this mode.
CHARGE MODE
Vibration Sensor Mode
Ignition Control Mode
Input Voltage Control Mode
The Ignition Control and Vibration Sensor modes are suitable for Constant Voltage Alternators, Smart
Alternators, Start Stop, Euro 5 and 6 engines, cars with Regenerative Braking.

Summary of 3 Control Modes Operation voltages

Input Voltage
< 9V
> 11V
< 9V
> 11V
< 12.8V
> 13.5V
12V CAR
Output Status
Cut OFF
Resume to On
Cut OFF
Resume to On
Cut OFF
Resume to On
24V CAR
Input Voltage
Output Status
< 18V
Cut OFF
> 22V
Resume to On
< 18V
Cut OFF
> 22V
Resume to On
< 25.6V
Cut OFF
> 27.0V
Resume to On