IMPORTANT WARNINGS
IMPORTANT SAFETY INSTRUCTIONS
Suncourt recommends professional installation of the Airiva (or by an accomplished DIY person)
Please read and save these entire instructions before starting the installation.
WARNING To reduce the risk of fire or electrical shock, do not use this fan device with a speed control of any
kind. This device is for general ventilating use only. Do not use with hazardous, toxic or flammable vapors.
WARNING To reduce the risk of fire, electric shock or injury to persons or animals, observe the following:
Use this unit only in the manner intended by the manufacturer. If you have any questions or doubts, contact a
qualified installer or Suncourt Inc. Before servicing or cleaning this unit, disconnect the power by unplugging it
from the 110-120 Volt AC outlet. If a suitable Ground Fault Interrupter (GFI) 110-120 Volt AC grounded outlet
is not within reach of the Airiva
power cord, a new GFI outlet needs to be installed. The installation of this
outlet must be done by a qualified person(s) in accordance with all applicable Codes and Standards. The Airiva
is equipped with a grounded plug. This safety feature must never be defeated.
WARNING For your safety and protection follow all instructions and adhere to applicable safety, building and
electrical codes.
WARNING Install this product inside a building or dwelling only.
WARNING Do not operate this product without ductwork or approved grilles being installed at the fan
openings to prevent contact with the fans. Contact with the operating fans will cause serious injury.
WARNING Do not install this product where it can come in contact with water from flooding or otherwise.
WARNING Protect the outside vent hoods from ingress of water from rain or other sources.
WARNING Never expose this product to air temperatures over 120°F (49°C).
INSTALLATION AND MAINTENANCE INSTRUCTIONS
Suncourt recommends installation of the Airiva
by a professional.
Please read and save these instructions in their entirety before starting the installation.
WHERE AND HOW TO MOUNT
The Airiva
should be mounted on shelf brackets that can easily support 75lbs.
DO NOT Set the Airiva
flat on a shelf. Condensation will occur between the surface of the Airiva
and the
shelf.
The minimum mounting height should be 8" off the floor to provide clearance for the condensate drain. For
convenience when servicing, mounting the Airiva
at chest height is recommended.
The Airiva should be mounted such that the latches for the door are on top. The hinges for the door should be
on the bottom of the unit and slightly hanging over the stand or shelf.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Airiva and is the answer not in the manual?

Questions and answers

Summary of Contents for Suncourt Airiva

  • Page 1 The Airiva should be mounted such that the latches for the door are on top. The hinges for the door should be on the bottom of the unit and slightly hanging over the stand or shelf.
  • Page 2: Electrical Power

    If moisture collects in the bottom of the Airiva, you should install the drain. You will need to make a 5/8" diameter hole in the bottom of the Airiva at the lowest point.
  • Page 3 Figure 3. NOTE: Suncourt recommends that you use metal duct to connect the Airiva . Flexible duct does not have a smooth inside surface. This creates turbulence in the airflow and will reduce the flow of air.
  • Page 4: Cleaning And Maintenance

    6", 24 VAC, damper. This damper will be installed in a "T" fitting on the fresh air intake side of the Airiva. When the fresh air to the house is below 45 degrees F (4 degrees C), it will open the damper, allowing some warm house air to mix with the incoming, cold fresh air.
  • Page 5 Place each plate, alternating the airflow channels on each layer. Lock the top plate in place with the metal rods, being careful not to bend them. Clean the screens of the outside vents as necessary.
  • Page 7 The Airiva heat exchanger core will accumulate an excessive amount of dust and dirt as a result of excessive airflow. Connecting the Airiva to the air supply and air return ducts of the forced air system requires a good understanding of airflow dynamics and the following supplies and equipment: Tools and Parts to be field supplied: 1.
  • Page 8: Mechanical Installation

    Airiva. Never connect both Airiva ducts to the same forced air system duct such as the main air supply duct or main air return duct. This may result in a large portion of the airflow to/from the Airiva just to flow around and around without bringing in fresh air or expelling stale air.
  • Page 9: Electrical Wiring

    3. The main forced air system fan is Off (motorized dampers will be fully Open). 4. The Airiva frost control, if installed, is disabled. *Partially close the manual dampers (if necessary) as little as possible to achieve an acceptable airflow balance in each the fresh and state airflow path.
  • Page 10: Manufacturer's Warranty

    YOU WILL HAVE TWO MANUAL DAMPERS AND TWO MOTORIZED DAMPERS INSTALLED The airflow through the Airiva is now in balance and will be within the specified airflow range whether the forced air system is operating or not.
  • Page 11 (c) a defective unit must be returned, prepaid, with proof of purchase after obtaining a return good authorization from Suncourt Inc. The unit must be returned in the original packaging and packaged as per enclosed instructions. This warranty is given in lieu of all other warranties,...
  • Page 12 Manufacturer reserves the right to change product specifications without notice. Airiva is a Trade Mark of Suncourt Inc. SUNCOURT INC. P.O. Box 40, 500 West Second Avenue. Durant IA 52747-0040 USA 1.800.999.FANS...

Table of Contents