SUNCOURT® RADON FAN MODEL: RDN04 & RDN04-3, RDK04 &
RDK04-3 INSTALLATION INSTRUCTIONS
READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE
READ AND SAVE THESE INSTRUCTIONS:
DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED.
CAUTION: BEFORE CARRYING OUT ANY MAINTENANCE OR SERVICING, ENSURE
THE UNIT IS DISCONNECTED FROM THE MAIN POWER SUPPLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS
OR DUST.
NEVER EXPOSE THIS FAN TO TEMPERATURES EXCEEDING 140° F (60° C).
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Do not use fan in hazardous environments where fan electrical system could provide
ignition to
combustible or flammable materials.
2. Do not use fan to exhaust explosive or corrosive gases.
3. Check voltage at the fan to insure it corresponds with product nameplate.
4. Normal operation of this device may affect the supply of fresh air needed for safe
operation of fuel burning equipment. Follow safety standards, codes, and heating
equipment manufacturer's procedures guide lines.
5. There are no user serviceable parts located inside the fan unit. Do NOT attempt to open
(this will void manufacturer's warranty). Return unit to the factory with original purchase
receipt for service after obtaining a Return Goods Authorization (RGA).
6. All wiring must be in accordance with local and national electrical codes. When installed
outside, power must be supplied from a GFCI (Ground Fault Circuit Interruptor).
7. Operate unit only in the manner intended. If you have questions, contact the
manufacturer.
8. Before servicing or cleaning the unit, switch power to off at service panel to prevent
power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device such as a tag to the service panel.
9. Installation work and electrical wiring must be done by a qualified person(s) in
accordance with all
applicable codes and standards, including fire-rated construction.
1 of 7
http://www.suncourt.com/Radon Print.html
1/2/2012 2:01 PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RADON RDN04 and is the answer not in the manual?

Questions and answers

Summary of Contents for Suncourt RADON RDN04

  • Page 1 Radon Print http://www.suncourt.com/Radon Print.html SUNCOURT® RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE READ AND SAVE THESE INSTRUCTIONS: DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. CAUTION: BEFORE CARRYING OUT ANY MAINTENANCE OR SERVICING, ENSURE THE UNIT IS DISCONNECTED FROM THE MAIN POWER SUPPLY.
  • Page 2 10. This unit has an unguarded impeller. Do not use in locations where the impeller is readily accessible to people or animals. 11. This unit can be used with the Suncourt VS100 or VS200 solid state speed control. (1) Running watts at zero static pressure...
  • Page 3 Radon Print http://www.suncourt.com/Radon Print.html INSTALLATION Retain original packaging. The fan can be mounted indoors or outdoors. (It is suggested that EPA recommendations be followed in choosing the fan location.) The fan may be mounted directly on the system piping or fastened to a supporting structure by means of mounting brackets provided.
  • Page 4 Radon Print http://www.suncourt.com/Radon Print.html The flexible couplings will provide means of disconnect for cleaning the impeller and also to isolate vibration. ELECTRICAL WIRING The fans operate on standard 120V 60 Hz AC. All wiring must be performed in accordance with the National Electrical Code and state and local building codes. A qualified electrician should perform all electrical work.
  • Page 5 Radon Print http://www.suncourt.com/Radon Print.html CONDENSATION & DRAINAGE Condensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point. This can occur at points where the system piping goes through unheated space such as an attic, garage or outside.
  • Page 6 SLAB COVERAGE The Suncourt Radon Fan provides coverage up to 2000 sq. ft. per slab penetration depending on type of sub slab material. If one slab penetration does not sufficiently mitigate the Radon then additional slab penetration points can be added as required.
  • Page 7 Suncourt shall not be liable for any direct, indirect, special, incidental or consequential damages arising from, or relating to, the fan or the performance of it. Suncourt’s maximum liability shall not exceed the amount of the purchase price of the fan. The sole remedy under this warranty shall be the repair or replacement of the product.