Caution! Do not block air ventilation holes.
Electromagnetic Interference (EMI) affects the transmission performance of a device.
By properly grounding the device to earth ground through a drain wire, you can setup
the best possible noise immunity and emissions.
Drain Wire with Lug
By connecting the ground terminal by drain wire to earth ground the device and
chassis can be ground.
Note!
Before applying power to the grounded device, it is advisable to use a
volt meter to ensure there is no voltage difference between the power
supply's negative output terminal and the grounding point on the device.
2.2.5.4
Wiring a Relay Contact
The following section details the wiring of the relay output. The terminal block on the
EKI-6333AC-A Series is wired and then installed onto the terminal receptor located
on the EKI-6333AC-A Series.
The terminal receptor includes a total of six pins: two for PWR1, two for PWR2 and
two for a fault circuit.
EKI-6333AC-A Series User Manual

Figure 2.14 Grounding Connection

PWR2
1A@24V
V2- V2+
P-Fail

Figure 2.15 Terminal Receptor: Relay Contact

15
Connection to
Grounding Point
DC12-48V
PWR1
V1- V1+