Replacing the communication module
▷ TORX screw driver size T20 required.
1
2
4
5
7
8
0 Replace the service cover on the electronic index.
 Push in a new screw locking cap, see page 14
(Spare parts). The body carrying out this task
should apply its own adhesive seal for sealing
the service cover.

Changing the SIM card

 Establish the optical communications link, see
page 8 (Establishing an optical communica-
tions link).
 Follow steps 1 to 6 of "Replacing the commu-
nication module", see section above.
▷ The SIM card slot can be found on the underside
of the module.
 Briefly press the SIM card to remove it from the
holder.
4 Insert the new SIM card in the same position
and lock it by pressing briefly.
5 To reinstall the communication module, follow
steps 7 to 11 of "Replacing the communication
module", see section above.
▷ The new SIM card requires a new PIN number.
6 Enter the new PIN number via the optical in-
terface. The procedure depends on your user
software.
WARNING
Risk of losing data!
Before changing the SIM card, ensure that the
GSM connection is not active!

Changing the battery

3
Risk of explosion in explosion-hazard areas!
6
▷ The battery is available as a spare part, see
9
▷ Prepare the index for changing the batteries.
▷ TORX screw driver size T20 required.
1
Battery for the communication module
▷ The battery can only be replaced when no data
Replace the battery as shown in the following steps:
4
7
0 Reprogram the battery parameters via the optical
▷ The procedure depends on your user software.
 Replace the service cover on the electronic index.
 Push in a new screw locking cap, see page 14
GB-9
WARNING
As a general rule, maintenance and repair work
should be avoided in explosive atmospheres.
Check that the electrical system complies with
the special electrical explosion protection re-
quirements.
When working on electrical equipment in an
explosion-hazard area, only design-approved
electrical operating equipment may be used.
Use original spare parts supplied by Elster
GmbH, see page 14 (Spare parts).
page 14 (Spare parts).
2
communication is taking place (check for the RF
module symbol in the display). Otherwise, data
communication will be cut off.
5
8
interface.
(Spare parts). The body carrying out this task
should apply its own adhesive seal for sealing
the service cover.
3
6
9