Fem22 Electronic Insert (Dc Pnp); Power Supply; Electrical Connection; Output Signal - Endress+Hauser Soliphant T FTM20 Technical Information

Vibronic
Hide thumbs Also See for Soliphant T FTM20:
Table of Contents

Advertisement

Soliphant T FTM20, FTM21

Power supply

Electrical connection

Output signal

Signal on alarm

Connectable load

Endress+Hauser

FEM22 electronic insert (DC PNP)

Voltage DC: 10...45 V
Ripple max. 5 V, 0...400 Hz
Current consumption max. 18 mA
Power consumption max. 0.81 W
Reverse polarity protection
Separation voltage: 2.2 kV
FEM22 overvoltage protection: overvoltage category II
Three-wire direct current connection
Preferred in conjunction with programmable logic controllers (PLC),
DI modules as per EN 61131-2.
Positive signal at electronics switch output (PNP);
Output blocked at point level.
IL
= Load current
(switched through)
< 100 μA
= Residual current
(blocked)
= Lit
= Not lit
L00-FTL2xxxx-07-05-
xx-xx-000
Output signal on power failure or in the event of device failure: < 100 μA
• Load switched via transistor and separate PNP connection
• Load current: max. 45 V (cyclical overload and short-circuit protection),
continuous max. 350 mA
• Residual current: < 100 μA (for blocked transistor)
• Capacitive load: max. 0.5 μF for 45 V, max. 1.0 μF for 24 V
• Residual voltage: < 3 V (for transistor switched through)
Fail-safe
Level
mode
MAX
MIN
1 2
3
(+)
F
0.5 A
Relais,
R
PLC, ...
L+ L–
PE (Ground)
U – 10 V...45 V(DC)
...
L00-FTM2xxxx-04-05-xx-xx-002
Output signal
LEDs
green yellow
L+
+
I
L
1
3
< 100 μA
1
3
L+
+
I
L
1
3
< 100 μA
1
3
L00-FTM2xxxx-04-05-xx-xx-003
FEM22
5