Crankcase Breather - Honda NAVI K74G-CBS 2019 Owner's Manual

New automatic vehicle
Table of Contents

Advertisement

3. Remove the "Secondary Air Filter" (3).
4. Wash the secondary air filter in clean,
nonflammable
solvent and let it dry thoroughly.
Never use gasoline or low flash point
solvents for cleaning the secondary air
filter. Fire or explosion could result.
5. Soak the secondary air-cleaner in engine
oil (SAE 10W-30) until saturated, then
squeeze out the excess oil.
6. Install the removed parts in the reverse
order of removal.
(1)
(2)
(1) Secondary Air Filter Housing Cover
(2) Screw
(3) Secondary Air Filter
Honda Motorcycle & Scooter India Pvt. Ltd.
or
high
flash
point
(3)

CRANKCASE BREATHER

Refer to the Safety Precautions on Page 38.
1. Open the "Clamp" (1) and remove
"Crankcase Breather Tube" (2) from
the air cleaner and drain deposits into a
suitable container .
2. Periodically clean up breather oil from
breather tube.
3. Reinstall the crankcase breather tube.
Service more frequently when riding in
rain, at full throttle, or after the vehicle
is washed or overturned. Service if the
deposit level can be seen in the transparent
section of the drain tube.
(1) Clamp
(2) Crankcase Breather Tube
(1)
(2)
45