7.5.3
Oil­level monitoring (optional)
The gear unit can be fitted with an oil­level monitor by means of a filling­level limit switch. The oil­level
monitoring device has been designed for checking the oil level when the gear unit is at a standstill, prior
to operating start.
Note
Wiring should be in such a way that, when the signal "Oil level too low" is given, the drive motor cannot
start and that a warning signal is emitted. During operation, any signal should be bridged.
7.5.4

Checking procedure

The following visual checks must be conducted and recorded when starting up:
Oil level
Leaktightness of the oil­cooling or oil­supply lines
Opening condition of the shut­off valves
Effectiveness of the shaft seals
Freedom of the rotating parts from contact
The tension pressures or pretensioning forces shown in item 6.3.2.2 must also be recorded in this
document.
Note
The record must be kept with these instructions.
7.6

Shutting down

Switch off the drive unit.
DANGER
Danger to life through switched­on installation
To carry out work on the gear unit, the gear unit must always be stopped.
The drive unit must be secured against being switched on accidentally (e.g. by locking the key switch
or removing the fuses from the power supply).
A notice should be attached to the ON switch stating clearly that work is in progress on the gear unit.
Start the gear unit and allow it to run briefly (5 to 10 minutes) approx. every 3 weeks (during a shut­down
period no longer than 6 months).
Treat the gear unit with preservative, see items 7.6.1 and 7.6.2 (before a removal from service for
a period exceeding 6 months).