PCB Diagram and Parts List
TB101-AC POWER
#1: AC POWER (L)
#2: AC POWER (N)
CN412-ROOM SENSOR
#1 : ROOM SENSOR
#2 : GND
CN301-DOWNLOAD
CN201-EEPROM
#1: GND
#3: DC5V
#4: EEPROM_SELECT
#5: EEPROM_SO
#6: EEPROM_SI
#7: EEPROM_CLK
CN311-2 WIRED SUB
5-2
CN101-EARTH
#1: EARTH
#1: DC310V
#3 : GND
#4 : DC15V
#5 : FAN RPM
#6 : RPM FEEDBACK
CN501-DISPLAY
#1: DC12V
#2: LED_0
#1: DC12V
#3: LED_1
#2: ERROR OUT (GND)
#4: LED_2
#3: DC12V
#5: LED_3
#4: COMP/OPER. OUT
#6: LED_4
(GND)
#7: LED_5
#8: REMOCON OUT
#9 : AUTO SWITCH
#10: REMOCON IN
#11: GND
#12: DC5V
#13: GND
CN806-LOUVER3/4
#1 : DC12V
#1: GND
#2~#5: LOUVER SIGNAL
#2: EXTERNAL CONTROL
#6 : DC12V
SIGNAL
#7~#10: LOUVER SIGNAL
CN411-FLOAT SWITCH
#1: FLOAT SWITCH SIGNAL
#1 : DC12V
#2: GND
#2~#5: LOUVER SIGNAL
CN401 -HUMAN
SENSING
#1: GND
#1: DC12V
#2: GND
#2: MAIN-HUMAN
#3: SPI SIGNAL (DC12V)
SENSOR COMM(TXD)
#3: MAIN-HUMAN
SENSOR
COMM(RXD)
#4: GND
CN701-BLDC MOTOR
CN140-FUSE CHECK
#1: FUSE CHECK Signal
#2: GND
CN808-EEV
CN81- COMP/ERROR
MONITOR
#1~#4: EEV SIGNAL
#5 : DC12V
#6 : DC12V
CN83-EXT CTRL
CN414-HUMIDITY
SENSOR
#1 : DC5V
#2 : GND
#3 : THERMISTOR
SENSOR
#4 : HUMIDITY SENSOR
CN805-LOUVER1/2
CN103-DRAIN PUMP
#1: DRAIN PUMP (DC12V)
#2: GND
CN801-SPI
TE04-COMMUNICATION
#1: COM1(F1)
#2: COM1(F2)
#3: V1(DC12V)
#4: V2(GND)
#5: COM2(F3)
#6: COM2(F4)
CN809-AUTO GRILLE
#1 : DC12V
#4 : REMOCON OUT
#5 : GND
CN807-LOUVER5
#1 : DC12V
#2~#5: LOUVER SIGNAL
CN413:THERMISTOR
#1 : EVA-IN SENSOR
#2 : GND
#3 : EVA-OUT SENSOR
#4 : GND
#5 : DISCHARGE SENSOR
#6 : GND
CN804-VENTILATOR
#1: DC12V
#2: VENT SIGNAL
OUTPUT(GND)