Four Directions Cassette Type - Samsung AC026RN1DKG Service Manual

System air conditioner single for europe (r32, heat pump)
Hide thumbs Also See for AC026RN1DKG:
Table of Contents

Advertisement

Troubleshooting

4-2-3 Four directions cassette type

Error Mode
Operation Defrost
Timer
Filter
X
X
X
Power reset
X
X
X
Error of room temperature sensor in the indoor unit (Open/Short)
X
X
Error of heat exchanger IN/OUT sensor in the indoor unit (Open/Short)
X
X
X
Error of fan motor in the indoor unit
Error of the outdoor temperature sensor
X
X
Error of the condenser temperature sensor
Error of the discharge temperature sensor
No communication for 2 minutes between indoor and outdoor unit
X
X
(communication error for more than 2 minutes)
X
Error of outdoor unit
X
X
Detection of the float switch
EEPROM error
EEPROM option error
X
Outdoor valve clogging error.
X
X
MDS (Motion Detecting Sensor) Error
Error due to connecting outdoor units
X
that do not support the Wind-Free function
4-14
Cause
• Check indoor temperature sensor connection.
• Check indoor temperature sensor's resistance value to see if it's short/open.
• Check EVA IN/OUT sensor connection.
• Check EVA IN/OUT sensor's resistance value to see if it's short/open.
• Check the connection of motor connector
• Check the speed of the motor fan
• Check indoor temperature sensor connection.
• Check indoor temperature sensor's resistance value to see if it's short/open.
• Check connection between indoor and outdoor heat exchangers'
communication cables
• Check error occurred with outdoor heat exchanger.
• TERMINAL Block thermal FUSE error.(OPEN)
• Check float switch connection.
• Check whether the drain has been filled with water.
• Check if there is damage with EEPROM component.
• Check the indoor model to set the options.
• Inspection for match between indoor and outdoor machine models
• High pressure check valve clogging.
• Check MDS
• Check outdoor main PBA S/W Check outdoor EEPROM
Samsung Electronics
Measures
Outdoor heat exchanger
compressor
-
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
-
-
Samsung Electronics
Product operation with error
Outdoor heat exchanger fan Indoor heat exchanger fan
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
Operation-off
-
-
-
-
Troubleshooting
Diagnosis method
-
-
-
-
-
-
-
-
-
-
-
-
: On
: Blink X : Off
4-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents