7.4

Start-up

Adhere to the operating instructions for the respective components.
1.
Check the material and compressed air lines to make sure they are undamaged and have a
secure fit.
2.
Switch on compressed-air supply provided by the system owner.
3.
Make sure that there is air pressure of 4 to 8 bar.
4.
Make sure that the fluid intake hose is dipped into the material.
Fig. 7: Compressed air controller
5.
NOTICE!
Risk of increased wear in idle mode!
During initial commissioning there is still air in the diaphragm pump and the supply
lines. In idle mode the diaphragm pump is subject to particularly high levels of wear.
To bleed the pressure controller ( Fig. 7/1), first set a low air pressure.
6.
Activate the extraction point (e.g. manual spray gun) until material escapes.
7.
After successful bleeding, set the desired fluid pressure with the pressure controller.
GB–26
Operating instructions
T-Dok-236-GB-Rev.3
mail@krautzberger.com, www.krautzberger.com