Conduit Connection - York TIWM006B21S Installation And Maintenance Manual

Inverter-driven multi-split system heat pump air conditioners
Hide thumbs Also See for TIWM006B21S:
Table of Contents

Advertisement

8.5

Conduit Connection

The conduit connection for this unit is shown below. Remove the front panel to connect the conduit.
TIWM006B21S to TIWM012B21S
(1) Hold both sides of the flat panel and lift it up.
Open the flat panel fully and slightly extend the right arm shaft outward. After the shaft is removed from
the front panel, pull the flat panel and remove it.
Press inward two portions as shown to remove the lower right corner cover.
(2) Remove the two (2) screw caps and then the two (2) screws on the lower side of the front panel. Pull
the lower side of the front panel forward to release the catch-fitting. Use caution when removing this
panel so as not to make contact with air outlet louver.
(3) Slightly lift the front panel up to release the catch-fitting (at four locations) on the upper side of the unit.
Then pull the front panel forward to remove it.
(4) Remove the screw securing the electrical box cover and open it.
P5417052
Flat Panel
Screw
Screw Cap
Catch-Fittings for Lower
Side of Front Panel
Do not use excessive force when disassembling.
Remove this screw
Electrical Box
Cover
Switch Cover
Electrical Box Cover
Lower Right Corner Cover
Press
Front Panel Holes
for Catch-Fitting
Condensate Pan Fitting
Electrical Box Cover
Unit
Switch Cover
Press to
remove
31