Inverter-driven multi-split system heat pump air conditioners
Hide thumbs Also See for TIWM006B21S:
Table of Contents

Advertisement

(2) Determine the direction for the piping connection according to the layout for the site of installation as
shown below.
Left Side of Indoor Unit
• For Left Side Piping
With the appropriate cutting tool, remove the left-side "knock-out" panel and smooth away any sharp
edges. Do this before the unit is mounted onto the wall.
NOTE:
If left side piping access is selected, the condensate pipe outlet should be left side and the mounting plate
downslope should be adjusted to left side. It does not change the mounting plate downslope to the left
side.
• For the pipe installation embedded in the wall, the positions for piping are as follows.
Refrigerant and Condensate Pipe Connection
Refrigerant and Condensate
φ d
Pipe Connection
(3) Secure the securing plate for pipes (accessory) as
shown in the figure at right. (only for 006 to 012 Type)
P5417052
Left Side Piping
Cutter for Plastic
Cut this portion.
Exterior Contour for Indoor Unit
φ d
b
Right Side of Indoor Unit
Rear Side Piping
Left Side Cover
Model
TIWM006B21S
TIWM008B21S
TIWM012B21S
TIWM015B21S
TIWM018B21S
TIWM024B21S
c
TIWM030B21S
Securing Plate
Unit: inch (mm)
a
b
c
1-3/4
25-1/8
4-3/16
(45)
(638)
(107)
1-3/4
25-7/8
4-3/16
(45)
(657)
(107)
1-5/8
37-7/16
5-9/16
(42)
(951)
(141)
Secure the securing plate onto
upper and lower catches.
Catches
fd
2-9/16
(65)
2-9/16
(65)
3-1/8
(80)
17