Advantage Controls MicroTron O Series Manual

Chemical metering pump

Advertisement

Quick Links

Manual
MicroTron
Series O
Chemical Metering Pump
Installation
Maintenance
Repair
Manual
Advantage Controls
4700 Harold Abitz Dr.
Muskogee, OK 74402
Phone: 918-686-6211
Fax: 888-686-6212
www.advantagecontrols.com
05/2019
email: support@advantagecontrols.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MicroTron O Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Advantage Controls MicroTron O Series

  • Page 1 Manual MicroTron Series O Chemical Metering Pump Installation Maintenance Repair Manual Advantage Controls 4700 Harold Abitz Dr. Muskogee, OK 74402 Phone: 918-686-6211 Fax: 888-686-6212 www.advantagecontrols.com 05/2019 email: support@advantagecontrols.com...
  • Page 2: Table Of Contents

    Manufacturer’s Product Warranty Advantage Controls warrants units of its manufacture to be free of defects in material or workmanship. Liability under this policy extends for 24 months from date of installation. Liability is limited to repair or replacement of any failed equipment or part proven defective in material or workmanship upon manufacturer’s examination.
  • Page 3: Introduction

    I. Introduction This manual covers all facets of operation of the Advantage MicroTron™ pump, including unpacking, mounting, electrical and plumbing connection, and start-up. Safety, maintenance and repair, warranty, and factory information is also provided. Please read this manual completely before proceeding. Observe safety protocols and heed all warnings and precautions.
  • Page 4: Unpacking

    The Advantage MicroTron™ pump has been shipped to you as a complete package, ready for installation. If shipping carton shows any signs of damage, notify the shipping company immediately upon receipt. Advantage Controls cannot be held responsible for damage from shipping. Unpack the carton and insure that the following items are present: 1.
  • Page 5: Plumbing

    6. The electrical installation of the controller must be performed by trained personnel only and conform to all applicable National, State and Local codes. 7. Operation of this product in a manner not specified by Advantage Controls may result in damage to equipment or persons.
  • Page 6 4. Suction Lift vs Flooded Suction Applications Suction Lift Installation Mount the MicroTron™ pump on the top of a molded tank, not to exceed 5 feet from pump to bottom of tank. Flooded Suction This installation is recommended for very low outputs, solutions that gasify and/or high viscosity solutions.
  • Page 7: Start-Up

    8. Optional Three Function Valve The optional 3-function valve injection assembly provides three functions in one injection valve assembly. Anti-siphon feature allows metering of liquids “down hill” or into the suction side of a circulating pump. It provides protection against an accidental application of suction pressure at the fluid injection point. Its Teflon coated diaphragm provides a positive anti-siphon action.
  • Page 8: Optional Features

    50spm x .000167gps x 1440 (minutes per day) = 12.02 gallons per day Reducing the stroke length will reduce the pump’s output again. If the example pump above had it’s stroke length reduced to 50% the 12.02 gallons per day output is reduced to 6.01. (Example: 12.02 gpd x 0.50 = 6.01 gpd) A higher product viscosity will reduce the output.
  • Page 9: Diaphragm Replacement

    Diaphragm Replacement 1. Remove fluid end cover by lightly prying it loose from the fluid end. 2. Remove the four screws attaching the fluid end to pump body. 3. Remove the fluid end from the pump body. 4. Unscrew the diaphragm from the pump shaft in a counter-clockwise direction. Be careful that diaphragm support ring does not fall out.
  • Page 10: Liquid End Diagram

    C. Liquid End Diagram Item Description Complete Head Kit Injection Valve Foot Valve Suction Valve Discharge Valve Bleed Valve Assembly Pump Head Pump Diaphragm Support Ring 10 Shaft Seal 11 Head Bolts 12 Priming Tube 13 Suction Tubing 14 Discharge Tubing 15 Weight Complete Head Kit includes items:...
  • Page 11: Pump Replacement Parts

    Replacement Parts Getting the right materials of construction for your spare parts is easy. Using positions 7-10 of the pump model number, example: O130X1-KFSV. Find the assembly needed and add the codes of your pump’s liquid end after the standard prefix part number for the assembly. Part Assemblies Item Description...
  • Page 12: Trouble Shooting Guide

    VII. Troubleshooting PROBLEM CAUSE REMEDY Pump does not achieve Air trapped in suction line Straighten suction line to eliminate high spots. or maintain prime Foot valve contaminated or improperly Inspect foot valve screen and assure that foot installed valve is in a vertical position below fluid level. Excessive lift Max suction lift is 5 feet with fluids of specific gravity of water;...
  • Page 13 Application Notes:...