Installation

WARNING
Please observe the following to ensure that neither
persons nor the gas meter are damaged during
installation and operation:
– Note the max. allowable operating pressure p
and measuring range Q
plate – p. 2].
– Note the permitted ambient temperature t
gas temperature t
, see [Type label/Index plate
g
– p. 2] or [Technical data – p. 5].
– The gas meter is suitable for mechanical ambient
conditions of Class M1 of Directive 2004/22/EC.
For gas meters with an Absolute ENCODER index,
Class E2 for electromagnetic ambient conditions
also applies.
– When installing the diaphragm gas meter BK with
integrated "Smart Valve", make sure that no dirt
particles get into the meter and thus into the valve.
– The yellow sealing sleeve protects the pressure
test point on the gas meter. It may only be opened
for connecting a pressure measuring line.
– Use seals made from tested materials. Elastomer
seals or asbestos-free flat seals from Elster are
recommended.
– For meters resistant to high temperatures, only
use seals tested to be resistant to high tempera-
tures.
– Only use the seals once.
– For installation and operation, note the applicable
national regulations and the directives of the gas
supply company. For Germany, the valid DVGW
Code of Practice G600 (DVGW-TRGI) applies.
– If the calibration seal has been damaged or re-
moved, the gas meter is no longer approved for
measurements which are subject to statutory
testing.
▷ If the gas meter is stored or installed outdoors,
protect the site against rain. Condensing humidity
is permitted.
1 Remove protective caps.
▷ Installation in the horizontal position: connectors
must be pointing upwards.
▷ Note direction of flow (arrow).
▷ The gas meter must not be in contact with ma-
sonry or other parts.
▷ Ensure that there is sufficient installation space.
▷ Ensure unobstructed view of the index.
▷ The seal faces on the screw unions must be clean
and damage-free.
▷ For the compression of seals and the resulting
tightening torques for the screw unions, the seal
manufacturers' specifications must be observed.
Tightening torques for the recommended flat seals
in conjunction with screw connectors pursuant to
DIN 3376-1 and 3376-2, see www.docuthek.com
→▷Elster-Instromet →▷Products →▷Gas measuring
max.
, see [Type label/Index
max.
and
m
devices → Diaphragm meters → Ergänzung für
Betriebsanleitung BK, Verschraubungen und An-
zugsmomente für BK-G1,6 bis BK-G25 (Supple-
ment for BK operating instructions, Screw unions
and tightening torques for BK-G1.6 to BK-G25)
(D).
 Install the gas meter free of mechanical stress.
▷ The gas meter marked with
in the equipotential bond when being installed in
a potentially explosive atmosphere, e.g. by con-
necting it to a grounded pipeline.
▷ If a pulse sensor IN-Z6x is used for pulse tap-
ping on the gas meter marked with
Data sheet for pulse sensor IN-Z6x (D, GB)
www.docuthek.com → Elster-Instromet → Prod-
ucts → Gas measuring devices → Diaphragm
meters →▷Pulse sensor IN-Z61 and the standard
EN 60079-14 (Explosive atmospheres).

Temperature test point

▷ Temperature sensors can be inserted into the
thermowells for measuring the gas temperature
in the meter housing.
1
 Secure each of the temperature sensors using
the capstan screw provided.
Connecting the pressure measuring
line
WARNING
In order to ensure that the gas meter is tight:
– The pressure test nipple must not be twisted, bent,
or otherwise manipulated.
– When installing, always secure the pressure test
nipple using a suitable spanner.
▷ Functional safety and reliability are ensured only if
the material combination of the screw connector
and the pressure line are intermatched.
▷ Only use the olive and the attached union nut
supplied. The olive is secured to the sealing sleeve.
▷ When re-ordering, use original Parker EO progres-
sive ring fittings PSR/DPR.
1
4
GB-3
must be included
2
2
3
5
– see

Advertisement