MCBA PARAMETERS FOR THE SPECIALIST

INFO MODE

INFORMATION ON THE INSTALLATION
To switch from Standby mode to Info mode, press "MODE" twice
Press the "STEP" key until you see the desired information.
The dot located behind the first position flashes to indicate that the boiler is in Info mode.
Description of the
Display
parameters
Flow temperature
T1 in °C
STEP
Return temperature
T2 in °C
STEP
Domestic hot water
temperature T3 in °C
STEP
Outside temperature
T4 in °C
STEP
Flue gas temperature
T5 in °C
STEP
Flow temperature
set-point calculated
in °C
STEP
Rate of increase of
flow temperature
in °C/s
STEP
Rate of increase of
return temperature
in °C/s
STEP
Rate of increase
of hot water
temperature in °C/s
STEP
Flow temperature of
2nd central heating
circuit
STEP
NA
STEP
NA
STEP
Description of the
Display
parameters
NA
STEP
Ionisation current
STEP
NA
STEP
NA
STEP
Internal MCBA
temperature
STEP
Number of CH
starts
[ x 10000]
STEP
Number of CH
starts
[ x 100]
STEP
Number of CH
starts
[ x 1]
STEP
Number of hours of
CH operation
[ x 10000]
STEP
Number of hours of
CH operation
[ x 100]
STEP
Number of hours of
CH operation
[ x 1]
STEP
Number of DHW
starts
[ x 10000]
STEP
EN • 23
Display
MODE
MODE
Description of the
Display
parameters
Number of DHW
starts
[ x 100]
STEP
Number of DHW
starts
[ x 1]
STEP
Number of hours of
DHW operation
[ x 10000]
STEP
Number of hours of
DHW operation
[ x 100]
STEP
Number of hours of
DHW operation
[ x 1]
STEP