Crown DLTM-40 Installation & Operation Manual page 15

Direct steam single and twin mixer kettles
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, DIRECT STEAM SINGLE & TWIN MIXER
KETTLE, MODELS DLTM-40 TO DLTM-100 AND DLTM-40-2 TO DLTM-100-2
7.0 MAINTENANCE (Continued)
SETTING UP HYDRAULIC SYSTEM FOR MIXING KETTLES
A. SETTING MIXER SYSTEM PRESSURE
1. On the operator panel, switch
"POWER" to on, "MIXER" to on, and
set mixer speed to "STOP".
2. Turn trim relief stem, item "B", completely in.
3. Increase the pump pressure by turning "A"
inwards, until gauge "D" reads 1700 psi. The
pressure must be 300 psi higher than the
pump setting.
4. Adjust trim relief "B" outwards until pressure
indicated on gauge "D" begins to drop.
5. Lock the trim relief "B".
6. Decrease the pump pressure by turning
"A" outwards, until gauge "D" reads 1400 psi
and lock in place.
Part No. 10040R4
Figure 2
15
2018-12-05