Crown EMTS-40 Installation & Operation Manual

Electric modular skillets

Advertisement

Quick Links

IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: ____________________
INSTALLATION & OPERATION
MANUAL
Electric Modular Skillets
EMTS-30 EMTS-40 EMTS-60
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read
the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
CROWN FOOD SERVICE EQUIPMENT
.
Division of Middleby Canada Company Inc
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
www.crownsteamgroup.com
Printed in Canada
MANUAL 10130R3

Advertisement

Table of Contents
loading

Summary of Contents for Crown EMTS-40

  • Page 1 Date Purchased: ____________________ INSTALLATION & OPERATION MANUAL Electric Modular Skillets EMTS-30 EMTS-40 EMTS-60 WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
  • Page 2: Important Notes For Installation And Operation

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 1.0 IMPORTANT NOTES FOR INSTALLATION AND OPERATION This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
  • Page 3: Table Of Contents

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes for Installation and Operation ....... . . 2 Service Connections .
  • Page 4: Service Connections

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 2.0 SERVICE CONNECTIONS Part No. 10130R3 2019-01-16...
  • Page 5 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 6: Installation Instructions

    Before installing, verify that the electrical service agrees with the specifications on the rating plate located on the left side panel as you face the front of the braising pan. If the supply and equipment requirements do not agree, contact your dealer or Crown Food Service Equipment Ltd.
  • Page 7 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 INSTALLATION INSTRUCTIONS (Continued) LEVELLING AND ANCHORING TILTING BRAISING PAN 1. Place tilting braising pan in the installation position. 2. Place a carpenter’s level on top of the braising pan and turn the adjustable feet to level braising pan side-to-side and front-to-back.
  • Page 8 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 ELECTRICAL CONNECTIONS (Continued) Before performing any maintenance disconnect the WARNING: electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.
  • Page 9: Operation Instructions

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 4.0 OPERATION INSTRUCTIONS WARNING: The tilting braising pan and its parts are hot. Use care when operating, cleaning and servicing the tilting braising pan. BEFORE FIRST USE Using a non-corrosive, grease-dissolving commercial cleaner, to clean the protective metal oils from all surface parts and the interior of the tilting braising pan.
  • Page 10 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 START-UP PROCEDURE 1. Ensure that the braising pan is in the DOWN position. 2. Turn THERMOSTAT dial to desired temperature. The red TEMPERATURE LIGHT will come on. 3. When braising pan has reached set temperature, the red TEMPERATURE LIGHT will go off and the heating elements will shut off.
  • Page 11: Cleaning Instructions

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 FIGURE 2 5.0 CLEANING INSTRUCTIONS WARNING: Disconnect electrical power supply before cleaning. After each use, allow the tilting braising pan to cool before cleaning. Keep exposed cleanable areas of the tilting braising pan clean at all times. Do not get water in electrical box or on any electrical component.
  • Page 12: Cooking Temperatures

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 6.0 COOKING TEMPERATURES Temperature ( F) Thermostat Setting Simmering 200 Maximum 1 - 4 Sautéing 225 - 275 5 - 6 Searing 300 - 350 7 - 8...
  • Page 13: Maintenance, Hydraulic System

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 7.0 MAINTENANCE The tilting braising pan and its parts are hot. Use care WARNING: when operating, cleaning and servicing the tilting braising pan. WARNING: Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit before performing any maintenance.
  • Page 14: Adjustments And Controls

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 8.0 ADJUSTMENTS AND CONTROLS ADJUST PAN SPEED There are three controls available on this power unit. The first is an adjustable relief valve mounted into the custom aluminum manifold block. The other two control the linear speed of the actuator.
  • Page 15: Troubleshooting

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 9.0 TROUBLESHOOTING BRAISING PAN HEATING ELEMENTS DO NOT COME ON: 1. Power supply not “ON”. 2. Pan not in down position. 3. Defective limit switch. 4. Defective thermostat.
  • Page 16 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 TROUBLESHOOTING - HYDRAULICS (Continued) 2. FOAMING OIL: Return of tank line not below fluid level. Fluid contamination. Suction leak to pump. 3. MOISTURE IN OIL: Fill pipes left open.
  • Page 17 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 TROUBLESHOOTING - HYDRAULICS (Continued) Relief valve set too high. Aeration of fluids in reservoir (return line above fluid level). Worn cam ring, damaged gear or faulty bearing. Reversed rotation.
  • Page 18: Safety Data Sheets

    INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 19 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 20 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 21 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 22 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 23 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 24 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...
  • Page 25 INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS, , EMTS-60 MODELS EMTS-30, EMTS-40 Part No. 10130R3 2019-01-16...