Ebyte E810-DTU User Manual page 21

Ethernet to rs485/rs232
Hide thumbs Also See for E810-DTU:
Table of Contents

Advertisement

Ethernet to 485/232
Click Read Parameters on the RF Parameter Settings interface to obtain the module's current RF parameter settings. Then you can configure the RF settings.
(2) Open two network debugging assistants, set the network debugging assistant protocol type to UDP Server, the network debugging assistant's server IP address is set
to the module's IP address, the network debugging assistant's server port is set to the module's local port, click Connect.
(3) Enter a string of data in the sending area of network debugging assistant A, click Send, you will see that network assistant B has received the same data in the
sending area of the serial port. Input a string of data in the sending area of network debugging assistant A, network assistant B also received the data. It realizes bidirectional
transparent transmission.
Copyright ©2012–2017,成都亿佰特电子科技有限公司
Figure 23 RF Parameter configuration settings
Figure 24 Data transparent transmission
E810-DTU User Manual