SELF TESTING MAINTAINED EMERGENCY ILLUMINATION SIGNS WITH WHITE LEDs
TECHNICAL CHARACTERISTICS
Mains voltage
Maximum power consumption
Battery (Ni-MH)
Battery protection
Indications
Recharging time
Minimum emergency duration
Light source intensity (230V) / (emerg.)
Degrees of cover protection
Produced in accordance with
Operation temperature range
Relative humidity
Construction materials
External panel's dimensions
External unit's dimensions
Typical weight
Guarantee
Description
The luminaire consists mainly from two parts.
The body, where all the electronics are located and the lamp-head
where the indication sign and the high efficiency LEDs are located.
Maintained/Non maintained selection capability
Power on the device and press continuously the TEST button for 10
seconds, until the led strip turns off. Release the button and after a
short emergency test, the device operates as non-maintained. If you
want to restore the previous condition (maintained operation), press
continuously the TEST button for 10 seconds, until the led strip
lights. Release the button and after a short emergency test, the
device operates as maintained illumination sign.
Installation
To install the illumination sign follow the installation instructions on
page 2.
Battery Charging
The battery charging is completely controlled. In this case, is
achieved the perfect battery maintenance , as well as the elongation
of its duration. When the battery has completely charged, it charges
with a maintenance current.
Battery Cut-off
The luminaire enters in this operation when
the mains power supply fails and battery has lost its energy. During
this operation the luminaire enters the idle state and battery
consumption is negligible, in order to be protected from deep
discharge.
Manual Test
The manual test can be conducted only if the mains power supply
and the battery is connected. By pressing the test button briefly an
operation test is initiated. During this test period all indication LEDs
are OFF.
Automatic Test
This test includes all the operations that provide the manual test and
is conducted automatically every 15 days. In order to be performed,
the mains power supply and the battery should be connected.
Automatic Autonomous Test
Page 1 from 4
(for LED MODULE specifications see page 4)
SLD-28/DZ
9 VA
Overcharging and deep discharging protection
Charge LED, Lamp LED, Fault LED, Test Button
100lm /100lm
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
280x120x15mm
680gr.
Thank you for your trust in our products
Olympia Electronics - European manufacturer
The Automatic Autonomous Test is conducted and measures the
luminaire`s back up operation. This test is conducted automatically
every six months. In order to be performed, the mains power supply
and the battery should be connected (the battery should be charged).
If the battery is not charged, the test is postponed until the battery is
completely charged. If during the Automatic Autonomous Test the
luminaire's duration is lower than the nominal, then the battery must
be replaced.
Back Up Operation
The autonomous duration of battery during emergency mode is at
least the one that is stated in the list of the first page. During
emergency mode, a LED strip test is also performed.
Resetting Errors
Push the Test button for >5 seconds, to delete all the indicated LED
errors. Then the luminaire enters regular operation mode.
Indication LED status (with connected mains power supply).
Charge
On: Good charge current.
Οff: No battery (No charging current or disconnected battery).
Lamp Fault
Οn: Faulty LED strip or back up circuit.
Off: Good LED strip or back up circuit.
Battery Fault
Οff: Battery OK.
Blink (With Charge LED ON): Autonomy or low battery problem (the
battery must be replaced).
Blink (With Charge LED Off):
No charging current or disconnected battery.
SLD-34/DZ
220-240V AC/50-60Hz
3.6V/1.5Ah
24h
3h
125lm /125lm
IP30
o
5 to 40 C
up to 95%
ABS/PC, aluminum, Acrylic plate
340x190x15mm
289x65x34mm
1020gr.
3 years (1 year for the battery)
SLD-44/DZ
9.5 VA
440x240x15mm
1380gr.
922044000_09_027

Advertisement

loading

Summary of Contents for olympia electronics SLD-28/DZ

  • Page 1 Typical weight 3 years (1 year for the battery) Guarantee Thank you for your trust in our products Olympia Electronics - European manufacturer Description The Automatic Autonomous Test is conducted and measures the The luminaire consists mainly from two parts.
  • Page 2 Installation instructions Remove the front plastic cover by unscrewing the two retaining screws. Pass the mains cables through the hole of the plastic base. Connect the live and the neutral wires to the terminal block as shown in the picture. Mount the device by installing the included mounting accessories in the holes or use the Α-3018 mounting springs for suspended seiling mounting.
  • Page 3 Changing the length of the panel’s cables (initial length 50cm.) To release the panel’s cables unfasten the screw of the holding system and push forward. Cut the desirable length to shorten the cable and to ensure the electrical connectivity strip the isolating wrap for about 2cm from the edge of the panel’s cable.
  • Page 4 Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid.

This manual is also suitable for:

Sld-44/dzSld-34/dz