Advertisement

Quick Links

www.zephyronline.com
Spruce
AK9834AS
AK9840AS
AK9846AS
AK9858AS
INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA.
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
APR19.0301 © Zephyr Ventilation LLC.
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr AK9834AS

  • Page 1 Spruce AK9834AS AK9840AS AK9846AS AK9858AS INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA. Model number: Serial Number: Date of Purchase: Sales Dealer: APR19.0301 © Zephyr Ventilation LLC. READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE ................LIST OF MATERIALS ..............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Specifications ............... Electrical ................. Installing the One Piece Insert ......Insert Preparation ............FEATURES & CONTROLS Rotary Controls ............MAINTENANCE Cleaning &...
  • Page 4: Safety Notice

    www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
  • Page 6: List Of Materials

    MODELS: AK9834AS, AK9840AS, AK9846AS AND AK9858AS PARTS SUPPLIED 1 - Insert hood body 2 - Baffle filters (3 for AK9846AS & AK9858AS) 4 - Halogen light bulbs (pre-installed) 1 - Dual internal blower (pre-installed) 1 - 10” round duct collar 1 - Hardware package HARDWARE PACKAGE CONTENTS Light Bulb Removal Wire Caps (3) #8 x 1/2” (12) M4 x 6mm (4)
  • Page 7: Ducting Calculation Sheet

    Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal T otal length x used 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
  • Page 8: Installation

    www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 30”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and efficiency.
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape. Some Ducting Options side wall cap w/ gravity damper side wall cap w/ gravity damper Soffit or crawl space Roof Pitch w/ Flashing & Cap...
  • Page 10: Specifications

    www.zephyronline.com 3/4 View (34”)12” (40”)15” (46“)18” (58”)27” elec. Top View (34”)12” (40”)15” (46“)18” (58”)27” elec. Back View...
  • Page 11: Electrical

    ELECTRICAL WARNING All Electrical work must be performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground.
  • Page 12: Installing The One Piece Insert

    www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the hood. If possible, power up and test all functions prior to installation. 1. Remove all packing materials and protective film prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel.
  • Page 13: Insert Preparation

    2. Remove grease tray by: 1) Pulling up on tray to 1. Remove baffle filters by: 1) Pulling filter toward release from bottom panel. 2) Lifting tray out of front of insert. 2) Pivoting rear of filter down. insert body. Bottom Panel Screws Locking Tabs 3. Remove left and right side spacer panels by 4.
  • Page 14: Rotary Controls

    www.zephyronline.com 1 Blower On/Off/Speed Selection 2 Lights Dim/Bright/Off 1 Blower On/Off/Speed Selection Rotate dial to change speed levels, (1) for low speed, (2) for medium speed and (3) for high speed 2 Lights Dim/Bright/Off Rotate dial to change light settings, (1) for dim light and (2) for bright light...
  • Page 15: Cleaning & Installing Filters

    SURFACE MAINTENANCE: Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth.
  • Page 16: Lights & Parts List

    www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. FIG 7. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are difficult to turn due to prolonged use, firmly attach the glass suction cup provided to the bulb or use a rubber/ latex glove and turn counter clockwise.
  • Page 17: Wiring Diagram

    MAX. USE ONLY TYPE MR16, GU10, 35W. HALOGEN LIGHT BULBS. AK9834AS, AK9840AS VOLTS MAX AMPS AK9846AS, AK9858AS Dual Motor 9 CIRCUIT DIAGRAM...
  • Page 18: Troubleshooting

    www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR SPRUCE Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2. Check the power connection with the unit is is not connecting properly. connected properly. 3. The switch board and control board wirings are 3. Make sure the wirings between the switch disconnected.
  • Page 19: Warranty

    Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to manufacturing defects subject to the exclusions and limitations below.
  • Page 20: Product Registration

    PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.