Advertisement

Available languages

Available languages

www.zephyronline.com
Vortex
AK9028AS
AK9034AS
AK9028AS290
AK9034AS290
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
APR14.0301 © 2014 Zephyr Ventilation
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr Vortex AK9034AS

  • Page 1 Vortex AK9028AS AK9034AS AK9028AS290 AK9034AS290 Model number: Serial Number: Date of Purchase: Sales Dealer: APR14.0301 © 2014 Zephyr Ventilation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options .......................... Electrical ................. Custom Hood Preparation & Installation ... Mounting the Liner ............FEATURES & CONTROLS Slide Controls ............... MAINTENANCE Cleaning &...
  • Page 4: Safety Notice

    www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
  • Page 6: List Of Materials

    www.zephyronline.com MODELS: PARTS SUPPLIED 1 - One piece liner 1 - Adjustable front panel 1 - Hardware package HARDWARE PACKAGE CONTENTS Light Bulb Removal #8 x 1/2” (8) Suction Cup (1) Wire Caps (3) PARTS NOT SUPPLIED - Ducting, conduit and all installation tools - Cable connector (if required by local codes) ZRC-9000...
  • Page 7: Ducting Calculation Sheet

    Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3-1/ 4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 6” Round, 1 Ft. 6” Round, 30 Ft.
  • Page 8: Installation

    www.zephyronline.com Minimum mount height between range top to cabinet bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the liner at the proper mounting height. Liners mounted too low could mounted too high will be hard to reach and will If available, also refer range manufacturer’s height i n .
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Some Ducting Options side wall cap side wall cap w/ gravity damper w/ gravity damper Soffit or crawl space...
  • Page 10 www.zephyronline.com *dimensions do not include 3/8” wide flange around the liner 3/4 View ” Top View ” 9/16 ” 3/8” Back View...
  • Page 11: Electrical

    ELECTRICAL WARNING how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
  • Page 12: Custom Hood Preparation & Installation

    www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the hood. If possible, power up and test all functions prior to installation. Recommended Side Panel Thickness: 3/4'' during installation to prevent scratches or damage to the stainless steel.
  • Page 13: Mounting The Liner

    FIG. 2 stainless steel screws. FIG. 2. WARNING: Make sure the surface you are securing the liner to is capable of holding the weight of AK90. Failure to do so may cause personal injury or damage to cooking surface or counter. Wood blocking may need to be added to custom hood base if additional support is needed.
  • Page 14: Slide Controls

    www.zephyronline.com Blower On/Off Speed Selection Lights Bright/Dim/Off I I I BLOWER ON/OFF/SPEED SELECTION 0 is off, I is low speed, II is medium speed and III is high speed. LIGHTS BRIGHT/DIM/OFF 0 is off, I is dim, and II is bright.
  • Page 15: Cleaning & Installing The Filter

    SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser.
  • Page 16: Ductless Recirculating

    www.zephyronline.com DUCTLESS RECIRCULATING (OPTION) Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the one piece liner functions in air “purifying” mode rather than exhausting the air. Fumes back into the kitchen. We recommend to always exhaust air outside of the home by employing existing or installing new duct work, possible should you use the liner in recirculating mode.
  • Page 17: Lights

    Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. latex glove and turn counter clockwise. For Zephyr part numbers please turn to page 19 of the manual. Bottom View...
  • Page 18: Troubleshooting

    www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR VORTEX Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 19: Fan Curve & Wiring

    Blower Fan Curve Model: AK90 (Vortex) AC Input: 120V, 60Hz Outlet Diameter: 6in 2.80 2.70 2.60 2.50 2.40 2.30 2.20 2.10 2.00 1.90 1.80 1.70 1.60 1.50 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 Flow rate (CFM)
  • Page 20 www.zephyronline.com Blower Fan Curve Model: AK90-290 (Vortex) AC input: 120V - 60Hz Outlet Diameter: 6in 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0 25 0.25 0.20 0.15 0.10 0.05 0.00 Flow rate (CFM) 1.5A...
  • Page 21: List Of Parts & Accessories

    DESCRIPTION PART # Replacement Parts Optional Accessories Recirculating Kit w/ Charcoal Filter ZRC-9000 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 22 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows:...
  • Page 23 Vortex AK9028AS AK9034AS AK9028AS290 AK9034AS290 Numéro de modèle: Numéro de série: Date d’achat: Détaillant: APR14.0301 © 2014 Zephyr Ventilation LISEZ ET CONSERVEZ CES INSTRUCTIONS...
  • Page 24 www.zephyronline.com...
  • Page 25 MISE EN GARDE DE SÉCURITÉ ........... LISTE DU MATÉRIEL ................ INSTALLATION Feuille de calcul pour le conduit ..........Espace libre et hauteur de montage ........Options d’installation pour le conduit ........................Électricité..................Préparation et installation de la hotte sur mesure ..
  • Page 26 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 27 ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
  • Page 28 www.zephyronline.com www.zephyronline.com MODÈLES: AK9028AS(290) et AK9034AS(290) PIÈCES FOURNIES 1 - Hotte monobloc 1 - Panneau avant ajustable 2 - Ampoules halogènes (préinstallées) 1 - Ventilateur interne avec registre (préinstallé) 1 - Trousse de quincaillerie MATÉRIEL INCLUS (1) Ventouse pour (8) #8 x ½" enlever l’ampoule (3) Capuchons de connexion PIÈCES NON FOURNIES...
  • Page 29 Longueur x Longueur x Pièces de conduit Pièces de conduit Total Total Nombre utilisé Nombre utilisé 3-1/ 4” x 10” 1 pi 6” 30 pi rect., droit embout mural circ./registre 6” circ., droit 1 pi 6” 30 pi chapeau de toiture circ.
  • Page 30 www.zephyronline.com www.zephyronline.com La hauteur de montage minimale ne devrait pas être moins de 26”. La hauteur de montage maximale ne devrait pas outrepasser 36”. Il est important d’installer la hotte à la hauteur de montage adéquate. Les hottes installées trop basses pourraient être endommagées par la chaleur en plus de présenter des risques d’incendie plus élevés tandis que les hottes i n .
  • Page 31 AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison N’utilisez que des conduits en métal. Fixez toutes les pièces du conduit avec des vis à...
  • Page 32 www.zephyronline.com www.zephyronline.com *les dimensions ne tiennent pas compte de la bride de 3/8" autour Vue 3/4 de la hotte ” Vue du haut ” 9/16 ” 3/8” Vue arrière...
  • Page 33 ÉLECTRICITÉ AVERTISSEMENT avec l’expérience technique et le savoir-faire nécessaire. Pour votre sécurité, enlevez le fusible ou ouvrez le disjoncteur de circuit avant de commencer Suivez le code électrique national ou local en vigueur. Alimentation électrique : Cet appareil requiert une alimentation électrique de 120V 60Hz et doit être connecté à un circuit terminal individuel dûment mis à...
  • Page 34 www.zephyronline.com www.zephyronline.com ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. Épaisseur recommandée Dans la mesure du possible, allumez l’appareil et assurez- du panneau latéral : vous du bon fonctionnement de toutes les fonctions avant de 3/4'' procéder à...
  • Page 35 FIG. 2 cinq (5) vis #8 x 1/2” en acier inoxydable. FIG. 2. l’encastrement peut soutenir le poids de la hotte AK90, sans quoi une personne pourrait se blesser, ou la surface de cuisson ou le comptoir pourraient être endommagés. Vous pourriez avoir à ajouter des pièces de renforcement en bois à...
  • Page 36 www.zephyronline.com www.zephyronline.com Allumer/Éteindre le ventilateur/Choix de vitesse Lumières Allumer/Veilleuse/Éteindre I I I Allumer/Éteindre le ventilateur/Choix de vitesse 0 pour éteindre, I pour la vitesse lente, II pour la vitesse moyenne et III pour la vitesse rapide. Lumières Allumer/Veilleuse/Éteindre 0 pour éteindre, I pour allumer et II pour la veilleuse.
  • Page 37 ENTRETIEN DES SURFACES: Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces.
  • Page 38 www.zephyronline.com www.zephyronline.com REPRISE D’AIR SANS CONDUIT (OPTIONNEL) Nous recommandons de toujours évacuer l’air à l’extérieur de la maison en utilisant le conduit en place ou, d’installer un conduit d’aération. cuisson lors de la reprise d’air. Procurez-vous l’ensemble de reprise d’air suivant : Numéro de pièce Qtée à...
  • Page 39 REMPLACEMENT DES AMPOULES ATTENTION : Les ampoules deviennent extrêmement chaudes lorsqu’allumées. Veuillez NE PAS les toucher avant de les avoir éteintes et laissées refroidir. Le contact avec les ampoules chaudes pourrait causer de sérieuses brûlures. Assurez-vous que l’alimentation électrique est coupée et que les ampoules ne sont pas chaudes. Enlevez les ampoules en les dévissant dans le sens contraire des aiguilles d’une montre.
  • Page 40 www.zephyronline.com www.zephyronline.com PROCÉDURES DE DÉPANNAGE POUR LA HOTTE VORTEX Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont fonctionne pas.
  • Page 41 Courbe de rendement du ventilateur Modèle : AK90 (Vortex) Entrée en CA : 120V, 60Hz Diamètre du conduit de sortie : 6" 2.80 2.70 2.60 2.50 2.40 2.30 2.20 2.10 2.00 1.90 1.80 1.70 1.60 1.50 1.40 1.30 1.20 1.10 1.00 0.90 0.80...
  • Page 42 www.zephyronline.com Courbe de rendement du ventilateur Modele : AK90-290 (Vortex) Entree en CA : 120V-60Hz Diametre du conduit de sortie : 6" 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0 25 0.25 0.20 0.15 0.10 0.05 0.00 Debit (pi3/min) Schéma de circuits...
  • Page 43 DESCRIPTION Nº DE PIÈCE Pièces de remplacement Ampoule MR16 (GU10) 35W (chaque) Z0B-0023 Accessoires optionnels Filtre à charbon de remplacement (chaque) Z0F-C090 Pour commander des pièces, visitez notre site Web au http://www.zephyronline.com ou communiquez avec nouspar téléphone au 1-888-880-8368...
  • Page 44 Zephyr Corporation (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présen- tes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...

Table of Contents