  • Page 1 Vortex AK9028AS AK9034AS AK9028AS290 AK9034AS290 AK9028AS-ES AK9034AS-ES Models: AK9028AS-ES AK9034AS-ES Model number: Serial Number: Date of Purchase: Sales Dealer: FEB15.0501 © 2015 Zephyr Ventilation LLC. READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options .......................... Electrical ................. Custom Hood Preparation & Installation ... Mounting the Liner ............FEATURES & CONTROLS Slide Controls ............... MAINTENANCE Cleaning &...
  • Page 4: Safety Notice

    www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
  • Page 6: List Of Materials

    www.zephyronline.com MODELS: AK9028AS, AK9028AS290, AK9028AS-ES AK9034AS, AK9034AS290, AK9034AS-ES PARTS SUPPLIED 1 - One piece liner 1 - Adjustable front panel 1 - Hardware package HARDWARE PACKAGE CONTENTS Light Bulb Removal #8 x 1/2” (8) Suction Cup (1) For Models: AK9028AS AK9034AS AK9028AS290 AK9034AS290...
  • Page 7: Ducting Calculation Sheet

    Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
  • Page 8: Installation

    www.zephyronline.com Minimum mount height between range top to cabinet bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the liner at the proper mounting height. Liners mounted too low could mounted too high will be hard to reach and will If available, also refer range manufacturer’s height i n .
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Some Ducting Options side wall cap side wall cap w/ gravity damper w/ gravity damper Soffit or crawl space...
  • Page 10 www.zephyronline.com *dimensions do not include 3/8” wide flange around the liner 3/4 View ” Top View ” 9/16 ” 3/8” Back View...
  • Page 11: Electrical

    ELECTRICAL WARNING how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
  • Page 12: Custom Hood Preparation & Installation

    www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the hood. If possible, power up and test all functions prior to installation. Recommended Side Panel Thickness: 3/4'' during installation to prevent scratches or damage to the stainless steel.
  • Page 13: Mounting The Liner

    FIG. 2 stainless steel screws. FIG. 2. WARNING: Make sure the surface you are securing the liner to is capable of holding the weight of AK90. Failure to do so may cause personal injury or damage to cooking surface or counter. Wood blocking may need to be added to custom hood base if additional support is needed.
  • Page 14: Slide Controls

    www.zephyronline.com Models: AK9028AS, AK9028AS290, AK9034AS, AK9034AS290 Blower On/Off Speed Selection Lights Bright/Dim/Off I I I BLOWER ON/OFF/SPEED SELECTION 0 is off, I is low speed, II is medium speed and III is high speed. LIGHTS BRIGHT/DIM/OFF 0 is off, I is dim, and II is bright. Models: AK9028AS-ES, AK9034AS-ES Blower On/Off Speed Selection Lights On/Off...
  • Page 15: Cleaning & Installing The Filter

    SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser.
  • Page 16: Ductless Recirculating

    www.zephyronline.com DUCTLESS RECIRCULATING (OPTION) MODELS: AK9028AS, AK9028AS290, AK9034AS, AK9034AS290 Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the one piece liner functions in air “purifying” mode rather than exhausting the air. Fumes back into the kitchen.
  • Page 17: Lights

    Access light bulb by removing light bulb lens cover by 1 screw. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. Replacement bulbs are available from Zephyr or specialty lighting stores. Purchase type: 13w Fluorescent GU-24 CFL, STS T3 13GUS...
  • Page 18: Troubleshooting

    www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR VORTEX Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 19: Fan Curve & Wiring

    Fan Curve Model: AK90 (Vortex) AC Input: 120V, 60Hz Outlet Diameter: 6in 2.00 1.90 1.80 1.70 1.60 1.50 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 Flow rate (CFM)
  • Page 20 www.zephyronline.com Blower Fan Curve Model: AK90-290 (Vortex) AC input: 120V - 60Hz Outlet Diameter: 6in 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0 25 0.25 0.20 0.15 0.10 0.05 0.00 Flow rate (CFM) 1.5A...
  • Page 21: Circuit Diagram

    Fan Curve Model: AK90-ES (Vortex ES) Working Speed Max. Speed AC Input: 120V, 60Hz Outlet Diameter: 6in 2.00 1.90 1.80 1.70 1.60 1.50 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 Flow rate (CFM) USE ONLY 13W, GU24 FLUORESCENT LIGHT BULBS.
  • Page 22: List Of Parts & Accessories

    www.zephyronline.com DESCRIPTION PART # Replacement Parts Models: AK9028AS-ES, AK9034AS-ES Optional Accessories, Models: AK9028AS(290), AK9034AS(290) Recirculating Kit w/ Charcoal Filter ZRC-9000 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 23: Warranty

    Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
  • Page 24: Product Registration

    PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.