Philips TE1.1E Service Manual page 20

Color television
Table of Contents

Advertisement

EN 20
8.
Option byte 1 (Op1)
PAL-BG
1: PAL BG available
0: PAL BG not available
Default setting = 1
PAL-DK
1: PAL DK available
0: PAL DK not available
Default setting = 1
PAL-I
1: PAL I available
0: PAL I not available
Default setting = 1
PAL-M
1: PAL M available
0: PAL M not available
Default setting = 0
PAL-N
1: PAL N available
0: PAL N not available
Default setting = 0
NTSC-M
1: NTSC M available
0: NTSC M not available
Default setting = 1
NTSC-443
1: NTSC 4.43 available
0: NTSC 4.43 not available
Default setting = 1
SECAM_BG
1: SECAM BG available
0: SECAM BG not available
Default setting = 1
Option byte 2 (Op2)
SECAM DK
1: SECAM DK available
0: SECAM DK not available
Default setting = 1
FRANCE
1: FRANCE available
0: FRANCE not
Default setting = 1
SYS-FR
1: System France available
0: System France not available
Default setting = 1
SYS-UK
1: System UK available
0: System UK not available
Default setting = 1
AV2
1: AV2 available
0: AV2 not available
Default setting = 0
AV-S
1: AV-S available
0: AV-S not available
Default setting = 0
AV3
1: AV3 available
0: AV3 not available
Default setting = 0
AV3S
1: AV3S available
0: AV3S not available
Default setting = 0
TE1.1E
Alignments
Option byte 3 (Op3)
JR
1: Stereo volume control via PWM-DACs enabled
0: Stereo volume control via PWM-DACs disabled
Default setting = 0
HP
1: reserved*
0: reserved*
Default setting = 0
Vbar
1: Volume bar OSD enabled
0: Volume bar OSD disabled
Default setting = 1
SubWoof
1: reserved*
0: reserved*
Default setting = 0
Presets
1: Predefined settings are available
0: Predefined settings are not available
Default setting = 1
Lock
1: reserved*
0: reserved*
Default setting = 1
Hotel
1: Hotel mode enabled
0: Hotel mode disabled
Default setting = 0
Option byte 4 (Op4)
16:9
1: 16:9 enabled
0: 16:9 disabled
Default setting = 0
110
1: 110 Deg. Picture tube
0: 90 Deg. Picture tube
Default setting = 0
Hpol
1: Polarity of the Horizontal sync for OSD is negative
0: Polarity of the Horizontal sync for OSD is positive
Default setting = 0
Vpol
1: Polarity of the Vertical sync for OSD is negative
0: Polarity of the Vertical sync for OSD is positive
Default setting = 0
Field
When set, the vertical sync for OSD is in the second half line at
the start of an even field. When not set in the first half line at the
start of an even field.
1: enabled
0: disabled
Default setting = 1
FEOut
1: CVBS signal always present on AV1
0: CVBS signal not always present on AV1
Default setting = 1
Swon
1: Last status enabled
0: Last status disabled
Default setting = 1
VGCheck
When service mode is activated vertical guard is switched off.
1: VG Check enabled
0: VG Check disabled
Default setting = 1