PINs with only 3 or 4 digits. An invalid PIN alarm feature sounds an alarm (three short
beeps) whenever an invalid PIN is entered. This feature is disabled by default. To
enable, enter *13*1*. To disable, enter *13*0*.
Door Monitoring: The system includes a number of functions that make it possible to
monitor the status of the door during operation. With the exception of the open duration
function, these features require that a door position switch (not included) be installed
on the door and connected to the control unit.
Open Duration: The open duration is the time period during which the door is released
(unlocked) after either a valid PIN is entered on the keypad or the remote release
button is pressed. The default open duration time is 5 seconds. To change the open
duration time, enter *20*N*, where N is from 1 to 60.
Anti-Follow: The anti-follow mode is provided to prevent the door from being re-opened
a second time during the open duration time period. This function is disabled by
default. To enable anti-follow, enter *21*1*. To disable anti-follow, enter *21*0*. When
this function is enabled, the door re-locks immediately after it closes, regardless of the
open duration setting.
Door Propped Alarm: The door propped alarm function sounds an alarm when the door
remains open for more than a specified time or until the door is closed. This function is
disabled by default. To enable the door propped alarm, set the door propped alarm
delay time by entering *22*N*, where N is 1 to 255. To disable the door propped alarm,
enter *22*0*.
Door Propped Alarm Duration: The door propped alarm duration can be set to sound
continuously either until the door closes or until a time out period expires. Enter
programming code *23*0* to set the door propped alarm to sound until the door closes.
To have the door propped alarm sound until a time out period expired or the door
closes (whichever occurs first), enter *23*N*, where N is 15 to 255.
Forced Door Alarm: The forced door alarm function sounds an alarm if the door is
opened without being released by the system. This function is disabled by default. To
enable the forced door alarm, enter *24*1*. To disable the forced door alarm, enter
*24*0*. The forced door alarm is silenced by entering the valid PIN on the keypad or by
disabling the forced door alarm function by entering programming code *24*0*.