8.1) Problems without error codes
Combustion noise too high
Gas supply type according
appliance gas type ?
Yes
Gas supply pressure (static /
dynamic) according IM ?
Yes
Check exhaustion system for
eventual recirculation of
combustion products (cross
contamination)
Problem solved ?
End
Without Front Cover
CO2 (G20) ≈ 5.5%
(+/-0.2%)
CO2 (G31) ≈ 6.6%
(+/-0.2%)
Temp gases máx ≈ 170ºC
Temp. gases min ≈ 45ºC
With Front Cover
Máx CO2 = CO2 without front
cover + 0.3 %
ATTENTION:
Adjustments of ΔP are done
without front cover
Page 56 from 76
No
Convert appliance according IM
(check existence of EF codes in
memory)
No
Assure gas supply pressure,
testing appliance at
maximum and minimum
Clearances for air admission
/ flue discharge according IM
/ Sealing between flue pipes
and appliance
No
Measure CO2 value (at flue
measurement point) in
maximum power with /
without front cover
Emissions according
specification ?
Yes
End
ATTENTION:
CO2 > nominal = flue
recirculation
CO2 increasing > 0.3%
difference from cover Off to
cover On = flue recirculation
6 720 814 719 SM FP_Australia 2017/04 EN
In case of need
contact gas supplier
Cross contamination
persist / Combustion
No
not ok
Adjust appliance by
confirming ΔP1 / ΔP2
according IM
Note: check air / gas
measurement
independently to be sure
reading is ≠ 0 and then
check ΔP