Values in P1 mode are settled according to the appliance selection and gas type from
factory. To check default value or to change parameter, press "Program" button when
inside of P1.
ΔP (kPa)
ΔP (kPa)
Table 24 – Values measured on gas manometer for low output models
ΔP (kPa)
ΔP (kPa)
Table 25 – Values measured on gas manometer for high output models
Page 40 from 76
Adjustment of air flow without
change gas conditions
Adjustment of gas flow
without change air conditions
Table 23 – P1 sub menus
Appliance
GWH 12
P1
GWH 16
GWH 20
GWH 12
P2
GWH 16
GWH 20
Appliance
GWH 16
P1
GWH 20
GWH 26
GWH 16
P2
GWH 20
GWH 26
6 720 814 719 SM FP_Australia 2017/04 EN
Range from 0 to 40
Spare part default setting is 20
Range from 0 to 40
Spare part default setting is 20
Natural Gas
Propane
0.46 – 0.50
0.63 – 0.67
0.37 – 0.41
0.63 – 0.67
0.33 – 0.37
0.44 – 0.49
0.05 – 0.08
0.05 – 0.08
0.05 – 0.07
0.05 – 0.07
0.04 – 0.08
0.05 – 0.08
Natural Gas
Propane
0.22 – 0.28
0.25 – 0.32
0.21 – 0.26
0.26 – 0.32
0.21 – 0.29
0.18 – 0.26
0.03 – 0.06
0.04 – 0.06
0.03 – 0.05
0.05 – 0.07
0.02 – 0.05
0.03 – 0.06