Bosch GWI-N Series Training And Service Information page 59

Fan pressurized instantaneous gas water heater for indoor and outdoor installation
Table of Contents

Advertisement

A1
Temperature inside room sealed box and detected by air flow NTC sensor is > 70ºC
Component Characteristic: NTC temperature sensor (220 kΩ type)
Warning Message
closed
Temperature inside
box is high
Refer to table with
values in Service
Manual
Power Reduction
Procedure
Start condition:
T air > 70ºC
Power lower in 5 % / 30 sec
Stop Condition:
T air < 70ºC
Note: when maximum power
reduction is 20 % or T air > 80ºC
E4 is displayed
See spare part list
Heat Cell includes heat
exchanger sealing with
burner / flue collector
Page 59 from 76
Appliance keeps operation and code is flashing until tap is
Check position of sensor (attached
at back cover of control unit)
NTC out of place and
touching hot surface ?
No
Measure the NTC electrical
resistance [R] (Ω)
[R] Ω = Current T air (ºC) ?
No
Replace wiring
Evidences of leakages
through sealing's or HE
overheat?
Yes
Correct problem by
inspecting and/or
replacing gaskets /
sealings in Heat Cell
6 720 814 719 SM FP_Australia 2017/04 EN
Yes
Correct position and fix
NTC in original position
Yes
Check origin of high
temperature inside box
No
End

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh 12 ctd e 31 f5Gwh 12 ctd e 23 f5Gwh 12 ctd e 23 f5 lGwh 12 ctd e 31 f5 lGwh 12 ctd e 23 f3 oGwh16 3 ct e23 f6 b s2405 ... Show all

Table of Contents