Amron 2810E-ATEX User Manual

Dual lock, atex rated chamber communicator

Advertisement

Quick Links

User Manual
for
Amron International, Inc.
Model 2810E-ATEX
Dual Lock, ATEX Rated Chamber Communicator
S/N ____________________
1380 Aspen Way, Vista California 92081-8349
United States of America
Phone: (760) 208-6500
Fax (760) 599-3857
Email:
sales@amronintl.com
Web:
www.amronintl.com
This manual and the information contained herein are provided for use as an operation and maintenance
guide. No license or rights to manufacture, reproduce, or sell either the manual or articles described
herein are given. Amron International, Inc. reserves the right to change specifications without notice.
Copyright© 2019 Amron International, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2810E-ATEX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amron 2810E-ATEX

  • Page 1 This manual and the information contained herein are provided for use as an operation and maintenance guide. No license or rights to manufacture, reproduce, or sell either the manual or articles described herein are given. Amron International, Inc. reserves the right to change specifications without notice. Copyright© 2019 Amron International, Inc.
  • Page 3: Table Of Contents

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator TABLE OF CONTENTS INTRODUCTION ........................... 1 SPECIFICATIONS ..........................1 ELECTRICAL ..........................1 MECHANICAL ..........................1 MODEL 2810E-ATEX - FRONT PANEL ..................2 MODEL 2810E-ATEX – INSIDE OF ENCLOSURE ..............3 ACCESSORIES ............................ 4 AMRON STANDARD HEADSET - MODEL 2460-31R ..............
  • Page 4: Introduction

    (Operator) and another volume control for the down-link (Chamber). Designed for a long and dependable service life, the 2810E-ATEX is housed in a rugged IEC Class 1, Zone 2 rated cast aluminum enclosure. The communicator comes standard with an 8 ohm MEDC ATEX rated speaker.
  • Page 5: Model 2810E-Atex - Front Panel

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator MODEL 2810E-ATEX - FRONT PANEL All of the controls for the Model 2810E-ATEX are located on the front panel with the electrical connections for power and the chamber accessible via cable located at the bottom of the enclosure.
  • Page 6: Model 2810E-Atex - Inside Of Enclosure

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator MODEL 2810E-ATEX – INSIDE OF ENCLOSURE 2810E-ATEX-UM REV 3.0...
  • Page 7: Accessories

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator ACCESSORIES Amron produces a series of accessories designed to operate with the 2810E-ATEX chamber communicator. AMRON STANDARD HEADSET - MODEL 2460-31R This light and comfortable headset is designed to extended wear by chamber occupants. The Model 2460-31R features an adjustable boom microphone, vinyl cushioned adjustable ear pads and a spiral cord that can be extended up to 8 feet (2.4 meters).
  • Page 8: Controls And Connections

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator CONTROLS AND CONNECTIONS Before using the 2810E-ATEX chamber communicator, the operator should be familiar with all the controls and connections. While reading this manual, you will find capitalized words such as PANEL SPEAKER.
  • Page 9: Front Panel Controls

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator FRONT PANEL CONTROLS The following controls and connections are located on the front panel of the 2810E-ATEX. 4.1.1 POWER SWITCH – Turns the power on/off to the communicator. It does not affect the chamber light power.
  • Page 10 Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator 4.2.5 EARTH GROUND – Black & white twisted wire pair that connects to the earth or safety ground. The chassis can be connected to earth ground using either this wire or the external grounding lug located on the right side of the chassis.
  • Page 11: Operation

    LOCK SELECTOR SWITCH to the INNER position and slowly turn up the OPERATOR VOLUME. Verify you can hear the chamber occupant through the HORN SPEAKER of the 2810E-ATEX. Press the PUSH-TO-TALK BUTTON and verify the operator can talk to the chamber occupant. Adjust the LOCK VOLUME control as necessary.
  • Page 12: Maintenance

    2810E-ATEX chamber communicator. GENERAL MAINTENANCE The 2810E-ATEX chamber communicator is designed to provide years of continuous, failure- free service when properly used and maintained. One of the most important things that can be done to extend the service life is to clean the communicator after use or when needed. If the equipment is on an extended work program, have the tender clean the equipment during slow work periods.
  • Page 13 If this solves the issue, then the communication cable in the original umbilical is damaged and needs to be replaced or repaired. If none of these solutions fixes the problem then contact Amron per section 2.2 for further assistance.
  • Page 14: Drawings

    If no communication is heard inside the chamber locks, there could be a broken wire inside the chamber communicator. Open the front panel and inspect. If that does not resolve the problem then contact Amron per section 2.2 for further assistance.
  • Page 15: Front Panel Parts Locator, Model 2810E-Atex

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator FRONT PANEL PARTS LOCATOR, MODEL 2810E-ATEX 2810E-ATEX-UM REV 3.0...
  • Page 16: Control Parts Locator, General & Mounting Dimensions

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator CONTROL PARTS LOCATOR, GENERAL & MOUNTING DIMENSIONS 2810E-ATEX-UM REV 3.0...
  • Page 17: Control Parts Locator, General & Mounting Dimensions

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator CONTROL PARTS LOCATOR, GENERAL & MOUNTING DIMENSIONS 2810E-ATEX-UM REV 3.0...
  • Page 18: Schematic, Chamber Communicator, Model 2810E-Atex

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator SCHEMATIC, CHAMBER COMMUNICATOR, MODEL 2810E-ATEX 2810E-ATEX-UM REV 3.0...
  • Page 19: Parts Lists

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator PARTS LISTS The parts lists include both mechanical and electrical parts. The following information will be useful in interpreting data which is not self-explanatory. REVISIONS The parts lists in this manual are for the current model of diver communicator as of the printing date.
  • Page 20: Model 2810E-Atex Top Assembly

    Model 2810E-ATEX Dual Lock, ATEX Rated Chamber Communicator MODEL 2810E-ATEX TOP ASSEMBLY Reference Part Number Description 520-0006-01 Enclosure, Model 2810E-ATEX 100-0001-01 Speaker, MEDC, ATEX, 8 Watt, 8 Ohm 570-1000-03 PCA for Chamber Communicator 520-0007-01 Power Supply, DIN MINI-PS, 12-24 DC...
  • Page 21: Limited Warranty And Service Policy

    Amron’s literature covering this product. Oxygen Treatment Hoods and accessories are excluded and limited to 90 days. Amron’s obligation under this warranty is limited to the repair of or replacement, at Amron’s option, of defective material. This warranty shall not cover defects which are the result of misuse, negligence, accident, repair or alterations.