EnOcean TCM 320U User Manual

868/902 mhz, transceiver module
Hide thumbs Also See for TCM 320U:
Table of Contents

Advertisement

Quick Links

USER MANUAL
TCM 300 / TCM 320 (868 MHz),
TCM 300U / TCM 320U (902 MHz) Transceiver Module
Observe precautions! Electrostatic sensitive devices!
Patent protected:
WO98/36395, DE 100 25 561, DE 101 50 128,
WO 2004/051591, DE 103 01 678 A1, DE 10309334,
WO 04/109236, WO 05/096482, WO 02/095707,
US 6,747,573, US 7,019,241
© 2019 EnOcean | www.enocean.com
TCM 300 / TCM 320 User Manual June 2019 | Page 1/52

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCM 320U and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EnOcean TCM 320U

  • Page 1 USER MANUAL TCM 300 / TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Observe precautions! Electrostatic sensitive devices! Patent protected: WO98/36395, DE 100 25 561, DE 101 50 128, WO 2004/051591, DE 103 01 678 A1, DE 10309334,...
  • Page 2 This information describes the type of component and shall not be considered as assured characteris- tics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifications, refer to the EnOcean web- site: http://www.enocean.com.
  • Page 3: Table Of Contents

    2.1 Basic functionality ..................6 2.2 Technical data TCM 300 / TCM 320 (868.300 MHz) ..........7 2.3 Technical data TCM 300U/ TCM 320U (902.875 MHz) ......... 7 2.4 Physical dimensions TCM 300x ................ 8 2.5 Physical dimensions TCM 320x ................ 8 2.6 Environmental conditions ................
  • Page 4 USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module 4.7.1 TCM 300x ....................35 4.7.2 TCM 320x ....................36 4.8 Tape & Reel specification TCM 300x ............... 36 AGENCY CERTIFICATIONS ................37 5.1 Radio Equipment Directive (RED) for the European Union .........
  • Page 5: Module Variants And Related Documents

    AN101: Power Supply Layout – Layout considerations for Line-Power  AN102: Antenna Basics – Basic Antenna Design Considerations for EnOcean based  Products AN403: Dolphin Migration - Replacing RCM 1xy / TCM 1x0 / TCM 2x0C by TCM 3x0 ...
  • Page 6: General Description

    The transceiver modules TCM 300x and TCM 320x enable the realization of highly efficient RF repeaters and transceivers for the EnOcean radio systems. The module provides several built-in operating modes. In addition repeater functionality (1 or 2 level) can be activated.
  • Page 7: Technical Data Tcm 300 / Tcm 320 (868.300 Mhz)

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Technical data TCM 300 / TCM 320 (868.300 MHz) Antenna TCM 320 : 8.6 cm whip TCM 300: whip or 50 Ω antenna mountable Frequency 868.300 MHz...
  • Page 8: Physical Dimensions Tcm 300X

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Physical dimensions TCM 300x Unless otherwise specified dimensions are in mm. Tolerances: PCB outline dimensions 0.2 mm All other tolerances 0.1 mm TCM 300x (pads on bottom side of PCB!) Physical dimensions TCM 320x Unless otherwise specified dimensions are in mm.
  • Page 9: Environmental Conditions

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module PCB dimensions TCM 320x (without pin connector): 36.5 x 18 x 5.5 mm TCM 300x: 22 x 19 x 3.1 mm Pin connector 16 pins, grid 2.0 mm (4.0 mm in length, ‫ٱ‬...
  • Page 10: Functional Description

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module FUNCTIONAL DESCRIPTION Pin out RF_WHIP XTAL 16MHz Antenna EO3000I balun TCM320/320C TOP VIEW The figure above shows the pin out of the TCM 300x / TCM 320x hardware. The pins are named according to the naming of the Dolphin chip to simplify usage of the DOLPHIN API.
  • Page 11: Pin Description And Operational Characteristics

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Pin description and operational characteristics HW Symbol Function Characteristics TCM 300x TCM 320x pin # pin # 1, 5, 7, 1, 16 Ground connection Must be connected to GND; see 4.5...
  • Page 12 USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module ADIO3 MODE 0: Sensitiv- Low sensitivity: LOW High sensitivity: HIGH Digital input, internal pull-up active MODE 1-4: LRN Enter/leave teach-in mode. See chap- ter 3.8...
  • Page 13: Gpio Supply Voltage - Iovdd

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module WSDADIO2 21 MODE 0-2, 4: not Digital output, internally set to LOW used MODE 3: CHAN- Digital output channel 3 NEL3 Max. output current: 2 mA @ IOVDD=3.3 V...
  • Page 14: Absolute Maximum Ratings (Non Operating)

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Inside TCM 320x the signals VDD and IOVDD are internally connected! Therefore the above mentioned issues have to be considered when writing own firmware based on API.
  • Page 15: Operating Modes

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Operating modes Mode Function Output signal description No. of channels Unidirectional serial SER_TX: UART output, supplies standard (ESP2) data blocks of information from all received EnOcean radio telegrams (9600 bps;...
  • Page 16: Mode Selection

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Mode selection The operating mode is defined at start-up of the module via a measurement of the voltage at ADIO0. As long as IDs are stored in ID memory, the operating mode can only be changed after deleting all IDs from memory, e.g.
  • Page 17: Repeater Configuration

    TCM 300U / TCM 320U (902 MHz) Transceiver Module Repeater configuration TCM 3x0 provides the option to activate a one or two-level repeater for EnOcean radio tele- grams. 1-level repeater: If a received telegram is a valid and original (not yet repeated), the tele- gram is repeated after a random delay.
  • Page 18: Suggested Reset And Programming Input Circuitry

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Suggested reset and programming input circuitry In order to ensure reliable operation it is recommended to connect both the reset and the programming input with a 10 kΩ resistor in parallel with a 10 nF capacitor to ground. This avoids spurious signal detection in very noisy environments and in situations where an ex- ternal programming header is provided.
  • Page 19: Confirmation Of Learning Mode

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module 3.9.2 Confirmation of Learning Mode Mode Confirmation No Learn capability LMI HIGH continuously, LRN_TOGGLE toggling every 1 s. LMI HIGH continuously, CHANNEL0 toggling every 1 s.
  • Page 20: Selecting The Next Channel

    After this, the receiver enters Learning Mode. 3.10 Remote management TCM 3x0 supports the remote management specification which is available from EnOcean upon request. This allows controlling the teach-in procedure via a Remote Config Control device. 3.10.1 Remote Management Control Commands (RMCC) All RMCCs supported.
  • Page 21: Remote Procedure Calls (Rpc)

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module 3.10.2 Remote Procedure Calls (RPC) Supported RPCs: Remote learn command, function code 0x201  Smart ACK: Read mailbox settings, function code 0x205, settings type 0x01 ...
  • Page 22: Smart Acknowledge

    The setup of the transmission timing allows avoiding possible collisions with data packages of other EnOcean transmitters as well as disturbances from the environment. Standard EnOcean telegrams consist of up to 3 identical sub-telegrams which are transmitted within 40ms. The transmission of an average sub-telegram lasts approximately 1.2ms. The delay be- tween the three transmission bursts is affected at random.
  • Page 23: Applications Information

     Lead glass or glass with metal coating, steel furniture  The distance between EnOcean receivers and other transmitting devices such as com- puters, audio and video equipment that also emit high-frequency signals should be at least 0.5 m A summarized application note to determine the transmission range within buildings is available as download from www.enocean.com.
  • Page 24: Antenna Options Tcm 300X

    Antenna options TCM 300x 4.2.1 Overview Several antenna types have been investigated by EnOcean. Please refer to our application notes AN102, and AN105 which give an overview on our recommendations. All TCM30x modules have been tested with whip antenna, and TCM300U with helical an- tenna in addition.
  • Page 25: Helical Antenna (Supplier: Enocean)

    Minimum GND plane: 35 mm x 30 mm Minimum distance space: 10 mm 902.875 MHz Limited modular approval is available. Please contact EnOcean to sign the mandatory lim- ited modular approval user agreement and for MOQ information. Design according to drawing below, connect to RF_WHIP.
  • Page 26: Chip Antenna (Supplier: Mitsubishi Material, Type Am11Dg-St01)

    Connect matching circuit to RF_50. Use High Q wire wound inductors, e.g. 0603 Murata LQW18A series. Matching circuits values: L1 = 3.9 nH; L2 = 33 nH, L3 = 12 nH. This antenna evaluation board is available upon request for use with EnOcean EDK 350 de- veloper kit.
  • Page 27: Antenna Options Tcm 320X

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Antenna options TCM 320x TCM320x is equipped and approved with a whip antenna. Specification of the TCM whip antenna: L=86 mm @ 868.3 MHz, L=64 mm @ 902.875 MHz ...
  • Page 28: Positioning Of The Whip Antenna

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module 4.3.1 Positioning of the whip antenna Positioning and choice of receiver and transmitter antennas are the most important factors in determining system transmission range.
  • Page 29 TCM 320U: Remove whip antenna and resistor, then mount SMA connector.  For 902 MHz module TCM 320U please note that a full radio approval needs to be performed if modules are used with external antennas other than the pre-installed whip antenna.
  • Page 30: Recommendations For Laying A Whip Antenna

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Recommendations for laying a whip antenna  PCB with GND PCB without GND Antenna too close to GND area   Antenna end led...
  • Page 31: Power Supply And Application Circuit Requirements

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Power supply and application circuit requirements In order to provide a good radio performance, great attention must be paid to the power supply and a correct layout and shielding. It is recommended to place a 22 µF ceramic ca- pacitor between VDD and GND close to the module (material: X5R, X7R, min 6.3 V to avoid...
  • Page 32: Layout Recommendations

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Layout recommendations The length of lines connected to I/Os should not exceed 5 cm. It is recommended to have a complete GND layer in the application PCB, at least in the area below the module and directly connected components (e.g.
  • Page 33: Tcm 300X Recommended Foot Pattern

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module 4.6.1 TCM 300x recommended foot pattern Top layer Solder resist top layer © 2019 EnOcean | www.enocean.com TCM 300 / TCM 320 User Manual June 2019 | Page 33/52...
  • Page 34 USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Solder paste top layer The data above is also available as EAGLE library. In order to ensure good solder quality a solder mask thickness of 150 µm is recommended.
  • Page 35: Soldering Information

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Soldering information 4.7.1 TCM 300x TCM 300x has to be soldered according to IPC/JEDEC J-STD-020C standard. TCM 300x shall be handled according to Moisture Sensitivity Level MSL 3 which means a floor time of 168 h.
  • Page 36: Tcm 320X

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module TCM 300x modules have to be soldered within 6 months after delivery! In general we recommend a no clean flux process. If washing is needed TCM 300 radio modules have a shield cover with small openings at the top of the edges.
  • Page 37: Agency Certifications

    TCM modules have been tested to fulfil following requirements: TCM 300 & TCM 320: RED (EU) TCM 30U & TCM 320U: FCC (US) / ISED (CA) Modules have been tested with described HW configuration in this user manual and EnO- cean pre-installed firmware.
  • Page 38 1% limit, which means less than 562.5 kByte gross bytes transmitted. Remarks: In order to transmit telegrams with EnOcean Equipment Profile (EEP) content, additional information(e.g. preamble, checksum, …) is need for the physical layer of the air interface (ISO/IEC 14543-3-10).
  • Page 39: Fcc (United States) Certification

    The module is designed to comply with, has been tested according to 15.231(a-c), and has been found to comply with each requirement. Thus, a finished device containing the TCM 300U / TCM 320U radio module can be operated in the United States without additional Part 15 FCC approval (approval(s) for unintentional radiators may be required for the OEM’s finished product), under EnOcean’s FCC ID num-...
  • Page 40 FCC ID:SZV-TCM320U IC:5713A-TCM320U  OEM Requirements In order to use EnOcean’s FCC ID number, the OEM must ensure that the following condi- tions are met: End users of products, which contain the module, must not have the ability to alter ...
  • Page 41 TCM 300U / TCM 320U (902 MHz) Transceiver Module The user manual for the end product must also contain the text given above. Changes or modifications not expressly approved by EnOcean could void the user's  authority to operate the equipment.
  • Page 42: Ised (Former Industry Canada) Certification

    TCM 300U / TCM 320U (902 MHz) Transceiver Module ISED (former Industry Canada) Certification In order to use EnOcean’s IC number, the OEM must ensure that the following conditions are met: Labelling requirements for Industry Canada are similar to those required by the FCC.
  • Page 43: Fcc Regulatory Statements

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module FCC Regulatory Statements This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera- tion.
  • Page 44: A Serial Interface

    A.3. EnOcean serial protocol (ESP2) When the module is in “Serial Interface” mode, it communicates via EnOcean Serial Proto- col 2 (ESP2) all EnOcean Equipment Profile (EEP) information from received RF telegrams. As long as no transmitter has been learned, all received EnOcean radio telegrams are transferred.
  • Page 45: Description Of Serial Data Structure

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module There are 4 types of ESP2 telegrams: RRT - Receive Radio telegrams (from AIR to Serial)  TRT - Transmit Radio telegrams (from serial to air) ...
  • Page 46: Radio Transmission/Reception Commands

    Alliance pursues standardization of communication profiles, ensuring that sensors from one manufacturer can communicate with receiver gateways of another, for example. End-users thus have the entire product portfolio - enabled by EnOcean - at their disposal. And product manufacturers can focus on their own special field.
  • Page 47: Command Telegrams And Messages

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module Command telegrams and messages Before sending the next command via serial interface please always wait for the response to the previous command from the module. The reaction time is below 5ms.
  • Page 48: Error Messages

    USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module A.3.5 Error messages Error Messages (RCT) ERR_TX_IDRANGE ERR_IDRANGE ERR_SYNTAX A.3.6 Command Encoding Bit 7 Bit 0 Standard message used to confirm that an action was performed...
  • Page 49 USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module SET_BASEID Bit 7 Bit 0 With this command the user can rewrite its ID range base num- 0xA5 0x5A ber. The most significant ID byte is BaseIDByte3. The informa- 0xAB tion of the 25 most significant bits is stored in FLASH.
  • Page 50 USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module SET_RX_SENSITIVITY Bit 7 Bit 0 This command is used to set the TCM radio sensitivity. 0xA5 0x5A In LOW radio sensitivity, signals from remote transmitters are 0xAB not detected by the TCM receiver.
  • Page 51 USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module RESET Bit 7 Bit 0 Performs a reset of the TCM microcontroller. 0xA5 0x5A 0xAB 0x0A ChkSum RD_SW_VER Bit 7 Bit 0 This command requests the TCM to send its current software...
  • Page 52 USER MANUAL TCM 300/ TCM 320 (868 MHz), TCM 300U / TCM 320U (902 MHz) Transceiver Module ERR_SYNTAX Bit 7 Bit 0 This telegram is sent automatically through the serial port after 0xA5 0x5A the TCM has detected a syntax error in a TCT telegram.

This manual is also suitable for:

Tcm 320Tcm 300uTcm 300

Table of Contents