EnOcean STM110C User Manual

Rf sensor transmitter module

Advertisement

Quick Links

Rhein Tech Laboratories, Inc.
360 Herndon Parkway
Suite 1400
Herndon, VA 20170
http://www.rheintech.com
Appendix K:
Manual
Please see the following pages.
Client:
EnOcean GmbH
Model:
STM110C
Standards:
FCC 15.231/IC RSS-210
ID's:
SZV-STM110C/5713A-STM110C
Report #:
2007284
Page 22 of 26

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STM110C and is the answer not in the manual?

Questions and answers

Summary of Contents for EnOcean STM110C

  • Page 1 Rhein Tech Laboratories, Inc. Client: EnOcean GmbH 360 Herndon Parkway Model: STM110C Suite 1400 Standards: FCC 15.231/IC RSS-210 Herndon, VA 20170 ID’s: SZV-STM110C/5713A-STM110C http://www.rheintech.com Report #: 2007284 Appendix K: Manual Please see the following pages. Page 22 of 26...
  • Page 2 DE 101 50 128 WO 2004/051591 DE 103 01 678 A1 EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 1/40...
  • Page 3 As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOcean does not assume responsibility for use of modules described and limits its liability to the replacement of modules determined to be defective due to workmanship. Devices or systems containing RF components must meet the essential requirements of the local legal authorities.
  • Page 4: Table Of Contents

    Encoding Scheme of CW and CP Input Pins ............17 Wake-up cycle time .................... 17 Redundant retransmission ................... 17 Solar Energy Balance Calculation ..............18 Radio Telegram of STM110C ................20 Frequency range and modulation scheme .............. 20 Transmission timing ................... 20 Serial Interface for module configuration ............21 Serial protocol ....................
  • Page 5 IC (Industry Canada) Certification ..............38 SPECIFICATION OF SS3513 SOLAR CELL .............. 39 EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 4/40...
  • Page 6: General Description

    TCM200 / TCM210C, this module can be easily integrated into op- eration and control units for the realization of various application-specific system solutions. The module is part of a powerful RF system solution from EnOcean for operation and con- trol applications. Because the RF transmitters are self-powered, maintenance-free RF sys- tems can be implemented.
  • Page 7: Technical Data

    Observe Precautions, electrostatic sensitive devices! EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 6/40...
  • Page 8: Physical Dimensions

    35.0 x 13.0 x 1.1 mm (for details see chapter 5) Antenna pre-installed 15 cm whip antenna Connector: 20 pins, dual row male, grid 1.27 mm Figure 2 : STM110C package outlines Environmental Conditions Operating temperature -25°C up to +65 °C Storage temperature -25°C up to +65 °C Humidity (PCB) 0% to 95% r.h.
  • Page 9: Functional Description

    Figure 3: STM110C block diagram Module power supply The supplied solar cell has been designed especially for the STM110C for maximum module performance at smallest dimensions. The active solar area is divided into two to provide independent module power supplies: V_SC1: Main power supply input.
  • Page 10: Power Control

    See chapter 2.5 for configuration of wake-up cycle times. EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 9/40...
  • Page 11: Processor

    The output LED is activated temporarily during telegram transmission. EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 10/40...
  • Page 12: Pin Description And Operational Characteristics

    Resistance to GND < 100 Ω EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 11/40...
  • Page 13 V_SC1 in series with a supplied solar panel (see chapter 3.6): Schottky diode of Type BAS 125 2.2 – 5.0 V to SOL1 of the STM110C solar cell (smaller area, see Figure 9). Or connect to another external energy source respectively.
  • Page 14: Absolute Maximum Ratings

    Humidity % r.h. Exceeding these values may destroy the module! EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 13/40...
  • Page 15: Equivalent Schematics Of Inputs And Outputs

    Equivalent schematic of wake-up cycle time inputs CW_0 to CW_1 CW_0 Threshold detector 1µ CW_1 6.8n EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 14/40...
  • Page 16: Equivalent Schematic Of Led Output

    (average) 0.50 0.45 Every 100 wake-up (average) 0.40 0.35 EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 15/40...
  • Page 17: Equivalent Schematic Of V_Sc2 Input

    < 1 mA < 1 mA LMV 358 LMV 358 V_REF V_REF EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 16/40...
  • Page 18: Encoding Scheme Of Cw And Cp Input Pins

    If applied in other (non-safety, non-security) applications a minimum of 10s be- tween periodic transmissions is required. In addition the device has to comply with the lower field strength limits of 15.231e). The limited modular approval of STM110C is not valid in this case. EnOcean GmbH Phone +49.89.67 34 689-0...
  • Page 19: Solar Energy Balance Calculation

    USER MANUAL V0.904 STM110C Solar Energy Balance Calculation The following diagrams are showing operational performance data of STM110C. charging time [h] Charging time [h] Charging at 1000 lx Charging at 1000 lx Charging at 1000 lx Charging at 200 lx...
  • Page 20 USER MANUAL V0.904 STM110C Figure 6: STM110C operation time in darkness (typ. @25°C) 1 sec timer Operating time in darkness [h] Operating time in darkness [h] 10 sec timer Operating time in darkness [h] Operating time in darkness [h] 100 sec timer...
  • Page 21: Radio Telegram Of Stm110C

    (315.0 MHz) can be approved in the USA and in Canada. The approval requirements can be found in chapter 4 of this paper. STM110C is based on ASK (amplitude shift keying) modulation with a bit rate of 125 kbit/s. Telegram content...
  • Page 22: Serial Interface For Module Configuration

    In order to activate the serial mode please take the following steps: 1. Connect LED pin to V_OUT pin 2. Activate STM110C using the timer or the WAKE inputs. The module will then enter the serial mode. It will receive information via the USR_RX (DI_3) pin and transmit information via the USR_TX (DI_2) pin.
  • Page 23: Serial Protocol

    (Last 8LSB from addition of all octets except sync bytes and checksum) EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 22/40...
  • Page 24: Command List

    The module answers with 3 telegrams: • INF_SYS_SW_VERSION • INF_SYS_ID_DEV_MAN • INF_SYS_AD_THRES EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 23/40...
  • Page 25 EnOcean! EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 24/40...
  • Page 26 Treshold at AD_1: 0..0xFF LSB AD_0_MIN_VARIATION: Treshold at AD_0: 0..0xFF LSB EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 25/40...
  • Page 27 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 ChkSum EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 26/40...
  • Page 28: Serial Data Reception Via Transceiver Modules Tcm 200C / Tcm 210C

    Serial Data Reception via Transceiver Modules TCM 200C / TCM 210C For a detailed description please refer to the User Manual of TCM200C/TCM210C. Type of STM110C protocol which is seen at the serial outputs of the receiver modules is “4BS” (4 Byte Sensor): Description of STM110C radio data content: = 7 dec.
  • Page 29: Applications Information

    The STM110C module requires some external circuitry configuration and connecting to the application-specific sensorics circuit. This external circuitry should easily find place on a small PCB that can be connected upside down to the EnOcean module via the STM dual row header. This allows the realization of very compact sensor units.
  • Page 30: Antenna Mounting

    Antenna Mounting Positioning and choice of receiver and transmitter antennas are the most important factor in determining system transmission range. The STM110C transmitter module is supplied with a soldered whip antenna as standard. By using that antenna, very compact sensor equipment can be implemented with good radio transmission characteristics.
  • Page 31: Transmission Range

    False ceilings with panels of metal or carbon fiber Lead glass or glass with metal coating, steel furniture The distance between EnOcean receivers and other transmitting devices such as comput- ers, audio and video equipment that also emit high-frequency signals should be at least 0.5m.
  • Page 32: Connecting The Solar Cell

    BAS 125-07W V_SC1 V_SC2 Figure 9: Connecting the solar cell EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 31/40...
  • Page 33: Solar Cell Handling, Soldering & Mounting

    STM110C Solar Cell Handling, Soldering & Mounting The EnOcean solar cell technology guarantees the highest stabilized efficiency values. At the front, the solar modules have a glass covering that protects the photovoltaic layer from the effects of the environment and weather. The rear features contacts for the electrical connection.
  • Page 34 Note 2: Lead wire breakage is excluded EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 33/40...
  • Page 35: Gluing

    The curing time of Loctite 403 is only 5 seconds once the solar cell is pressed onto the PCB. Positioning must be finished by then! EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 34/40...
  • Page 36: Corrosion Protection

    The cells (strips), which produce the least current due to shade, determine the total module current. EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 35/40...
  • Page 37: Using An Alternative Power Supply, E.g. Battery

    TCM200C/TCM210C serial interface. For example this can be realized as follows. Recommendation for the realization of a learn push button: EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 36/40...
  • Page 38: Agency Certifications

    OEM Requirements In order to use EnOcean’s FCC ID number, the OEM must ensure that the following condi- tions are met. EnOcean GmbH Phone +49.89.67 34 689-0...
  • Page 39: Ic (Industry Canada) Certification

    The user manual for the end product must also contain the text given above. Changes or modifications not expressly approved by EnOcean could void the user's au- thority to operate the equipment.
  • Page 40: Specification Of Ss3513 Solar Cell

    USER MANUAL V0.904 STM110C SPECIFICATION OF SS3513 SOLAR CELL EnOcean GmbH Phone +49.89.67 34 689-0 Subject to modifications Kolpingring 18a +49.89.67 34 689-50 STM110C User Manual V0.904 82041 Oberhaching info@enocean.com February 18, 2008 2:00 PM Germany www.enocean.com Page 39/40...