EN 14
5.
TPS10.1A LA

5. Service Modes and Fault Finding

Index of this chapter:

5.1 Test Points

5.2 Service Modes
5.3 Stepwise Start-up
5.4 Software Upgrading
5.5 Fault Finding and Repair Tips
5.1
Test Points
As most signals are digital, it will be difficult to measure
waveforms with a standard oscilloscope.
Perform measurements under the following conditions:
Service Default Mode.
Video: Colour bar signal.
Audio: 3 kHz left, 1 kHz right.
5.2
Service Modes
The Service Mode feature is split into five parts:
Factory Mode.
Customer Service Mode (CSM).
The Factory mode offer features, which can be used by the
Service engineer to repair/align a TV set. Some features are:
Make alignments (e.g. White Tone), reset the error buffer
(Factory Mode).
The CSM is a Service Mode that can be enabled by the
consumer. The CSM displays diagnosis information, which the
customer can forward to the dealer or call centre. In CSM
mode, "CSM", is displayed in the top right corner of the screen.
The information provided in CSM and the purpose of CSM is to:
Increase the home repair hit rate.
Decrease the number of nuisance calls.
Solved customers' problem without home visit.
Note: For the new model range, a new remote control (RC) is
used with some renamed buttons. This has an impact on the
activation of the Service modes. For instance the old "MENU"
button is now called "HOME" (or is indicated by a "house" icon).
5.2.1
General
Next items are applicable to all Service Modes or are general.
Table 5-1 Factory mode overview
Item Item value
0
Main-MCU Ver
1
Bootloader Ver
2
Sub-MCU Ver
3
EEPROM Ver
4
Date
5
ModelName
6
Scaler
7
Panel Type
8
Source
9
Auto Color
10
W/B Pattern
11
SSC
12
Enable
13
LVDS Span
14
LVDS Step
15
ADC
16
Gain
17
Offset
18
ColorTemp
18
Scaler
2013-Sep-06
Service Modes and Fault Finding
Default value
32"
39"
42"
Description
TPS1011A_2.01
Main-MCU Version
V0.01
Bootloader Version
V0.01
SUB-MCU Version
V0.01
EEPROM Version
Dec 20 2012
Software release date
32PFL3
39PFL
42PFL
Model name
008
3008
3008
MST6931XP
Scaler model
TPT315
TPT39
TPT42
Display model
B5-A04
0J1_HJ
0H2_H
2
1L02
VN01
TV
Input source
GO
Only need to do automatic correction input source of effective,otherwise it is not action
OFF
W/B Pattern
SSC
OFF
Enable on/off
35.0KHz
LVD Span
2.00%
LVD Step
YPbPr(SD)
ADC
RGB
RGB
RGB
ADC Gain
RGB
RGB
RGB
Offset RGB
Normal
The current set of color temperature
MST6931XP
Scaler model
Software Identification, Version, and Cluster
The software ID and version will be shown in the main menu
display of CSM.
The screen will show: "AAAAB-X.YYY", where:
AAAA is the chassis name: TPS1011A x.yyy.
B is the region indication: E = Europe, A = AP/China, U =
NAFTA, L = LATAM.
X is the main version number: this is updated with a major
change of specification (incompatible with the previous
software version). Numbering will go from 1 - 99 and
AA - ZZ.
- If the main version number changes, the new version
number is written in the NVM.
- If the main version number changes, the default settings
are loaded.
YYY is the sub version number: this is updated with a minor
change (backwards compatible with the previous
versions). Numbering will go from 000 - 999.
- If the sub version number changes, the new version
number is written in the NVM.
- If the NVM is refreshed, the software identification,
version, and cluster will also be written to NVM.
5.2.2

Contents of the Factory mode:

Purpose
To perform extended alignments.
Specifications
Displaying and or changing Panel ID information.
Various software alignment settings.
Testpattern displaying.
Public Broadcasting Service password Reset.
etc.

How to Activate the Factory mode

To activate the Factory mode, use the following method:
Press the following key sequence on the remote control
transmitter: from the "Home screen" press "1999", directly
followed by the "Back" button. Do not allow the display to
time out between entries while keying the sequence.
After entering the Factory mode, the following items are
displayed,
back to
div. table

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents