Troubleshooting - Kettler 0193321-2100 Assembly Instructions Manual

Palma fire pit table
Table of Contents

Advertisement

Troubleshooting

Problem
Cause
Igniter pin and burner are wet
Igniter battery is incorrectly inserted
Heating
Igniter pin is broken
unit won't
light
Electrode wire is loose or disconnected
Electrode wire is shorting between
valve and igniter pin
No gas flow
Regulator isn't connected securely to
the tank
Burner
won't light
Gas flow is obstructed
while using
a match
Burner ports are clogged
Heating
Flame is obstructed at burner ports
unit emits a
lot of black
smoke
Regulator hose is kinked
No gas flow
Sudden
drop in gas
Excess flow safety valve has been
flow
activated
High or gusting winds
Flame
No gas flow
blows out
Excess flow safety valve has been
easily
activated
Solution
Dry off with a soft cloth
Check which direction the battery is
inserted
Contact Bond Manufacturing for a
replacement part
Reconnect wire to the igniter box
located inside the table behind the
igniter box
Contact Bond Manufacturing for a
replacement part
Check that the gas tank isn't empty
Tighten regulator connection to the
gas tank
Check all hoses for kinks and bends
Turn all gas flow connections off. Insert
an opened paper clip (or similar item)
into each of the burner ports to clear
them out.
Check that all burner ports are free of
any small lava rocks/pumice stones/
LavaGlassm' pieces
Straighten hose of all bends or kinks
Check that the gas tank isn't empty
Turn the control knob to the'offt
position. Close the tank valve and
disconnect propane gas tank. Turn the
control knob to'high'; wait 1 minute.
Turn the control knob back to the 'off'
position. Reconnect propane gas tank.
Light the fire unit as indicated in the'To
Light' section of this manual.
Increase flame to'high'
Check that the gas tank isn't empty
See 'sudden drop in gas flow' above

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

0193321-5510

Table of Contents