1.4 RMON Configuration Example

I. Network requirements
Agent is connected to a configuration terminal through its console port and to a remote
NMS across the Internet.
Create an entry in the RMON Ethernet statistics table to gather statistics on
GigabitEthernet 4/2/2, and logging is enabled after received bytes exceed the specified
threshold.
II. Network diagram
Figure 1-1 Network diagram for RMON
III. Configuration procedure
# Configure RMON to gather statistics for interface GigabitEthernet 4/2/2.
<Sysname> system-view
[Sysname] interface GigabitEthernet 4/2/2
[Sysname-GigabitEthernet4/2/2] rmon statistics 1 owner user1-rmon
[Sysname-GigabitEthernet4/2/2] quit
# Display RMON statistics for interface GigabitEthernet 4/2/2.
<Sysname> display rmon statistics GigabitEthernet 4/2/2
Statistics entry 1 owned by user1-rmon is VALID.
Interface : GigabitEthernet4/2/2<ifIndex.157>
etherStatsOctets
etherStatsBroadcastPkts
etherStatsUndersizePkts
etherStatsFragments
etherStatsCRCAlignErrors : 0
etherStatsDropEvents (insufficient resources): 0
Packets received according to length:
64
256-511: 0
# Create an event to start logging after the event is triggered.
<Sysname> system-view
: 0
: 0
: 0
: 0
: 0
,
65-127
,
512-1023: 0
, etherStatsPkts
, etherStatsMulticastPkts : 0
, etherStatsOversizePkts
, etherStatsJabbers
, etherStatsCollisions
: 0
,
128-255
,
1024-1518: 0
1-6
Chapter 1 RMON Configuration
: 0
: 0
: 0
: 0
: 0

Advertisement

Table of Contents
loading

Table of Contents