Saurya SLAM Hornet EM 1LED Instructions For Safe Use page 4

Table of Contents

Advertisement

CE
= Valid production quality system approved and notified by VTT (Finnish Notified Body, listed
0537
by EC)
= Certified for explosion hazardous areas
II
= Certified for use in areas excluding mines
2
= Equipment category (suitable for Zone 1 & 21 and Zone 2 & 22)
G
= Certification taking account explosion hazardous GASES
D
= Certification taking account explosion hazardous DUSTS
Explanation of marking for explosion hazardous area due to Gases (Ex e ib mb op is IIC T4 Gb):
Ex = Certified for use in explosion hazardous areas
e
= Explosion protection method increased safety (of certain components)
ib = Explosion protection method intrinsic safety (of certain components)
mb = Explosion protection method encapsulation (encapsulating ignition sources)
op is = Explosion protection method optically inherently safe (visible or infrared radiation that is
incapable of producing sufficient energy under normal or specified fault conditions to ignite a
specific hazardous athmosphetic mixture). This definition is analogues to the term
"intrinsically safe" applied to electrical circuits
IIC = Equipment group (including explosion hazardous areas of IIA, IIB and IIC gases)
T4 = Maximum inside temperature of the unit is 135°C (within the ambient temperature range of
-20°C...+40°C)
Gb = Explosion Protection Level (EPL) marking for "HIGH" level of protection. Equipment for
explosive GAS atmospheres, which is not a source of ignition in normal operation or during
expected malfunctions
Explanation of marking for explosion hazardous area due to Dusts (Ex tb op is IIIC T 90 ° C Db):
Ex = Certified for use in explosion hazardous areas
tb = Explosion protection method "protection by enclosure"
IIIC = Equipment group for all dusts
T90 ° C = Maximum OUTSIDE surface temperature of the unit is 90 °C (within the ambient
temperature range of -20°C...+40°C)
Db = Explosion Protection Level (EPL) marking for "HIGH" level of protection. Equipment for
explosive DUST atmospheres, which is not a source of ignition in normal operation or during
expected malfunctions
CE
II 2 G Ex e ib mb op is IIC T4 Gb
0537
II 2 D Ex tb op is IIIC T90 ° C Db
4/16
IP 66