Saurya SLAM Hornet EM 1LED Instructions For Safe Use page 11

Table of Contents

Advertisement

In-built sockets are recommended when the illuminated area is notably large, complex or not enough
wiring points are available. Linking the units in series save time, amount of cable and provide an
opportunity to build a chain of lights to provide enough illumination in the darkness.
®
When linking SLAM
1) Connect the first luminaire to the power supply and power it up.
2) Then connect the other luminaries to each other one by one and power them up individually
3) The in-built socket is only for chaining SLAM
Luminaires should be powered up in series and powering up the whole chain as one need to be
avoided.
Amount of lights which may be connected with each other depends on the supply voltage.
Competent person of the operator shall control and accept the temporary electrical installation
at the site.
Before connecting SLAM
1. The total length of the light chain does not exceed 66 meters. Please see additional detail
below the chart.
2. The total current of the electrical installation does not exceed 16A.
Here you may see general and theoretical guide-lines for linking SLAM
2
3x1.5mm
(or 3x2.5mm
Please note that even if the voltage drop allows certain amount of luminaries to be linked
together, too long chain of luminaries may affect the ability of the fuses in the electrical input
to work properly in a fault situation. Therefore it is not recommended to chain luminaries to a
longer chain than 66m measured from the protective fuse (when the electrical supply is
protected with C-curve fuse). Please refer to local applicable laws and requirements for
electrical installations.
The SHEM control gear protects itself against excessive voltage drops (numerous linking) by switching
itself off. If too many units are connected to the chain, some units of the chain will switch off. You may
start up by unplugging the last units on the line.
Hornet units together, please take the following steps:
®
Hornet luminaries together, please ensure the following points:
2
) cable:
Supply
voltage
luminaire
SHEM1LED
230 V
SHEM1LED
110 V
SHEM1LED
42 V
SHEM1LED
24 V
11/16
®
Hornet units.
Type of
luminaires in series
(30 W)
(30 W)
(30 W)
(30 W)
®
Hornet luminaires with 5 m
Number of
9
9
9
9

Advertisement